[Table/Fig-5]:
Comparison of dimensional accuracy of group I casts (Premolar site) with master model using three types of impression trays.
Group I | Group II | Premolar | ||||
---|---|---|---|---|---|---|
Buczco-lingual | Mesio-distal | |||||
Mean ± SD | Difference | Mean ± SD | Difference | |||
Group I Medium body |
IA Metal Dual Arch |
Mean ± SD % difference p value |
4.148± 0.058 - - |
0.055± 0.058 1.3% 0.014, S |
3.294± 0.054 - - |
-0.027± 0.054 0.8% 0.15, NS |
IB Plastic Dual Arch |
Mean ± SD % difference p value |
4.146± 0.091 - - |
0.058± 0.091 1.4% 0.08, NS |
3.161± 0.069 - - |
0.106± 0.069 3.3% <0.01, S |
|
IC Custom Tray |
Mean ± SD % difference p value |
4.198± 0.009 - - |
0.005± 0.009 0.1% 0.11,NS |
3.259± 0.026 - - |
0.008± 0.026 0.2% 0.38,NS |
|
ANOVA F P |
IA/IB/IC | - | 2.28 0.12,NS |
- | 17.3 <0.01,S |
|
(Difference In Accuracy Amongst Various Tray Groups) | IA-IB IA-IC IB-IC |
- - - |
0.99,NS 1.19,NS 0.16,NS |
- - - |
<0.01,S 0.32,NS <0.01,S |
*Anova test