Tabulated rate constants for the POR‐catalysed hydride and proton transfer data shown in Fig. 4

Pressure (bar) [POR]am) k obs hydride (s−1) k obs proton (s−1)
H D H D
1 50 2.26 ± 0.21 × 106 1.01 ± 0.12 × 106 2.39 ± 0.18 × 104 1.10 ± 0.05 × 104
250 52 2.11 ± 0.18 × 106 1.03 ± 0.13 × 106 2.31 ± 0.23 × 104 0.96 ± 0.08 × 104
500 60 2.12 ± 0.17 × 106 0.99 ± 0.17 × 106 2.11 ± 0.21 × 104 0.93 ± 0.07 × 104
750 70 2.05 ± 0.12 × 106 0.99 ± 0.12 × 106 2.10 ± 0.10 × 104 0.91 ± 0.14 × 104
1000 85 2.01 ± 0.20 × 106 1.02 ± 0.06 × 106 2.02 ± 0.08 × 104 0.90 ± 0.11 × 104
1250 110 1.80 ± 0.12 × 106 1.11 ± 0.21 × 106 1.89 ± 0.09 × 104 0.86 ± 0.11 × 104
1500 156 1.99 ± 0.25 × 106 1.14 ± 0.17 × 106 1.71 ± 0.12 × 104 0.81 ± 0.09 × 104
1750 200 1.85 ± 0.20 × 106 1.29 ± 0.26 × 106 1.55 ± 0.17 × 104 0.83 ± 0.10 × 104
2000 260 2.02 ± 0.15 × 106 1.56 ± 0.31 × 106 1.36 ± 0.26 × 104 0.99 ± 0.12 × 104
a

The enzyme concentration used to maintain a saturated ternary complex (see Fig. 3).