Skip to main content
. 2016 Feb 21;44(2):335–345. doi: 10.1002/jmri.25177

Table 2.

Distributions of Response to Each Stimuli Combination and Statistical Inferences Comparing Each Stimulus to the Baseline Air‐Only State

Air only Mean ± SD Air/Cb Mean ± SD (P‐value) Ox/Cb Mean ± SD (P‐value)
‘Carbogen‐light’ (2%), n = 9
Median correlation coefficient 0.13 ± 0.03 0.14 ± 0.04 0.15 ± 0.05
(0.19) (0.08)
Median signal deviation (%) 0.77 ± 0.24 0.90 ± 0.28 0.96 ± 0.38
(0.16) (0.13)
Median RMS BOLD signal (%) 0.29 ± 0.08 0.34 ± 0.13 0.34 ± 0.13
(0.15) (0.14)
Percentage pixels activated (P < 0.05) 38.4 ± 15.7 45.8 ± 16.1 47.2 ± 21.2
(0.15) (0.08)
Carbogen (5%), n = 10
Median correlation coefficient 0.11 ± 0.02 0.13 ± 0.02 0.13 ± 0.02
(0.10) (0.04a)
Median signal deviation (%) 0.60 ± 0.16 0.68 ± 0.15 0.67 ± 0.15
(0.13) (0.11)
Median RMS BOLD signal 0.21 ± 0.05 0.24 ± 0.06 0.25 ± 0.06
(0.09) (0.03a)
Percentage pixels activated (P < 0.05) 27.9 ± 13.6 39.2 ± 10.0 38.7 ± 12.5
(0.10) (0.04a)
a

Significant P‐value.