Skip to main content
. 2016 Jul 18;17:295. doi: 10.1186/s12891-016-1138-0

Table 5.

Intra-rater and inter-rater reliability and measurement error estimates of the SFInX

Bland-Altman analysis
Reliability ICC2,1 (95 % CI) SEM MDC95 Mean difference (95 % CI) Limits of Agreement
Intra-rater 0.96 (0.94 to 0.97) 3.9 10.8 0.1 (−1.2 to 1.3) −10.6 to 10.8
Inter-rater 0.91 (0.63 to 0.97) 5.8 16.1 5.1 (2.1 to 8.0) −7.3 to 17.4
Kappa %
Inter-rater item agreement 0.42 to 1.00 40-100 %
Dichotomous items (n = 5) 0.62 to 1.00 90-100 %
Polytomous items (n = 8) 0.42 to 0.92 40-95 %

ICC Intra-class correlation coefficient, CI Confidence Interval, MDC Minimal Detectable Change, SEM Standard Error of Measurement