Skip to main content
. Author manuscript; available in PMC: 2017 Jul 1.
Published in final edited form as: Neurosurgery. 2016 Jul;79(1):83–99. doi: 10.1227/NEU.0000000000001175

Table 3.

Published results for the endovascular treatment of dolichoectatic basilar trunk aneurysms.

First author Last author Year, journal Total # of
fusiform BA/VBJ
aneurysms
# of Basilar
Trunk
aneurysms
Vertebro-basilar
junction
aneurysms
Devices used Deaths Ischemic
Complications
Hemorrhagic or Mass
Effect Complications
Complications not otherwise
specified
Angiographic Cures
Byrne, J Kamran, M 2010, PlosOne 10 3 7 SILK 2 0 1 (mass effect from aneurysm thrombosis – led to death) NA
Lubicz, B Leclerc, X 2010, Stroke 3 3 0 SILK 0 1 (branch occlusion) 0 1
Raphaeli G Lubicz B 2011, Neurosurgery 10
[16 purely vertebral artery aneurysms not included]
8 2 SILK
ENTERPRISE
LEO
SOLITAIRE
COILS
3 NA NA 1 treatment failure (died before treatment)
1 with transient hemiparesis at 2 weeks
1
Ertl L Fesl G 2014, AJNR 6 2 4 PIPELINE
SILK, LEO
4 (two addt’l with mRS 5) 3 1 – brainstem compression (following pneumonia) 0 1
Monteith S Jabbour P 2014, JNS 7 4 3 PIPELINE 1 1 0 0 2
Meckel S Klisch J 2013, Neurosurgery 6 0 6 PIPELINE (n=9)
SILK (n=1)
4 3 ischemic strokes 1 mass effect
1 hemorrhage
1 flow diverter construct thrombosis 2
Siddiqui A Levy E 2012, JNS 7 7 0 SILK (n=1)
PIPELINE (n=6)
4 5 1 (SAH) NA 2
Van Oel L Peluso J 2013, AJNR 13 NA NA Mix: Neuroform, Enterprise, LEO, SILK, and coiling 3 3 0 1 – MI during anesthesia 9
Fischer, S Henkes, H 2014, Neurosurgery 37 17 20 PIPELINE NA NA NA NA 16 of 25 with DSA
Toth, G Hui F 2014, JNIS 2 2 0 PIPELINE 1 2 strokes
(1 died, 1 mRS of 5)
0 NA 1 (secondary to construct thrombosis and occlusion)
Munich S Lopes D 2014, JNS 12 NA NA PIPELINE 1 2 strokes 0 2 patients with new hemiparesis
1 patient with new nystagmus/dizziness (ambulatory at 2 mos.)
9
Total BA trunk aneurysms Deaths (in all aneurysms treated) Ischemic Complications (in all aneurysms treated) Hemorrhagic or Mass Effect Complications (in all aneurysms treated) Complications not otherwise specified
46 23 20 5 7 38 of 123 total aneurysms cured

FD = flow diversion

SILK = SILK FLOW DIVERSION DEVICE

PIPELINE = PIPELINE EMBOLIZATION DEVICE (FLOW DIVERTER)