Skip to main content
. 2016 May 3;291(30):15740–15752. doi: 10.1074/jbc.M115.709402

FIGURE 7.

FIGURE 7.

Determination of voltage dependence of the slow gate in WT and mutant Cx50 hemichannels. Square voltage pulses were applied to determine voltage dependence. Oocytes maintained in a holding potential of +20 mV were subjected to hyperpolarizing pulses from 20 to −60 mV. Hemichannel currents recorded in oocytes expressing Cx50 (A), Cx50_E42Q (B), and Cx50_F43E (C) mutants. D, graph depicting I(V)/Imax relation of WT Cx50 (black), Cx50_E42Q (green), and Cx50_F43E (brown) mutants. The solid lines represent the fitting of the data to Equation 7 and using the mean values in Table 5. Current traces and corresponding voltage traces have the same color.