Table 3.
Band responsivities for the IB wavelength ranges of VIIRS bands M1 through M7. The responsivities for the laboratory measurements come from the SpMA and the SIS100. The comparisons show the differences from SIRCUS.
| VIIRS Band | SpMA Band Responsivity1 | SIRCUS Band Responsivity1 | Responsivity Difference SpMA-SIRCUS (%) |
|---|---|---|---|
| M1 | 19.392 | 19.427 | −0.18 |
| M2 | 24.421 | 23.321 | 4.72 |
| M3 | 27.286 | 26.660 | 2.35 |
| M4 | 36.855 | 35.399 | 4.11 |
| M5 | 50.815 | 49.701 | 2.24 |
| M6 | 84.892 | 84.068 | 0.98 |
| M7 | 111.470 | 110.028 | 1.31 |
Units: DN/(W m−2 sr−1 μm−1)