Skip to main content
. 2016 Jul 27;6:30390. doi: 10.1038/srep30390

Table 2. SAXS data-collection and scattering-derived parameters.

SAXS analyses
Data-collection parameters
 Instrument P12 beam line (PETRA-III, DESY)
 Wavelength (nm) 0.124
s range (nm−1) 0.02–4.8
 Exposure time (s) 0.045
 Concentration range (mg/mL) 0.5–2.0
 Temperature (°C) 20
Structural parameters
 I(0) (relative) [from p(r)]* 63,360.0
Rg (nm) [from p(r)] 4.93
 I(0) (relative) [from Guinier]* 62,494.4 ± 124.65
Rg (nm) [from Guinier] 4.74 ± 0.33
Dmax (nm) 20.0
 Porod volume estimate (nm3) 519.79
 Dry volume of a monomer calculated from sequence (nm3) 67.56
Molecular mass determination
 Molecular mass Mr (kDa) [from I(0) using p(r)] 287.8
 Molecular mass Mr (kDa) [from I(0) using Guinier] 283.8
 Calculated monomeric Mr from sequence 55.8
Software employed
 Primary data reduction PRIMUS
 Data processing PRIMUS
Ab initio analysis GASBOR
 Validation and averaging PRIMUS
 Rigid-body modelling BUNCH
 Computation of model intensities CRYSOL
 Three-dimensional graphics representation PyMOL

*After normalization to a concentration of 1 mg/mL.