Table 8. Experts Judgment of Operational Error and Multiple Failure.
Event | Fuzzy numbers proposed by each expert | ||
---|---|---|---|
Flange is not tightly clipped (B15) | Expert1 | Expert 2 | Expert 3 |
(0.2,0.3,0.4,0.5) | (0.1,0.2,0.3,0.5) | (0.2,0.3,0.4,0.5) | |
Expert 4 | Expert 5 | ||
(0.1,0.2,0.3,0.4) | (0.1,0.2,0.3,0.5) | ||
Operational error (B19) | Expert 1 | Expert 2 | Expert 3 |
(0.1,0.2,0.3,0.5) | (0.2,0.3,0.4) | (0.1,0.3,0.4,0.5) | |
Expert 4 | Expert 5 | ||
(0.2,0.3,0.4,0.5) | (0.2,0.3,0.5) | ||
V-4 is not closed (B21) | Expert 1 | Expert 2 | Expert 3 |
(0.2,0.3,0.4) | (0.1,0.3,0.4,0.5) | (0.1,0.2,0.3,0.4) | |
Expert 4 | Expert 5 | ||
(0.1,0.3,0.5) | (0.1,0.3,0.4,0.5) | ||
Ignition (CE1) | Expert 1 | Expert 2 | Expert 3 |
(0.1,0.3,0.4) | (0,0.2,0.3,0.4) | (0.1,0.2,0.4) | |
Expert 4 | Expert 5 | ||
(0.1,0.2,0.3,0.5) | (0.1,0.2,0.3) | ||
Ventilation(CE2) | Expert 1 | Expert 2 | Expert 3 |
(0.1,0.3,0.4,0.5) | (0.1,0.2,0.3,0.4) | (0,0.1,0.2,0.3) | |
Expert 4 | Expert 5 | ||
(0,0.1,0.3,0.4) | (0.1,0.2,0.3,0.4) | ||
Alarm(CE3) | Expert 1 | Expert 2 | Expert 3 |
(0.1,0.2,0.3,0.5) | (0.1,0.2,0.3,0.4) | (0,0.1,0.3,0.4) | |
Expert 4 | Expert 5 | ||
(0,0.1,0.2) | (0,0.1,0.2,0.3) |