. 2016 Jul 29;16:45. doi: 10.1186/s12871-016-0218-x

Table 3.

Results of the spirometry outcomes at baseline (T0) and 30 min after the interscalene block (T30) comparing the anterior and the posterior puncture approaches

Spirometry variable Puncture approach T0 T30
Median (Q1, Q3) Median differenceanterior-posterior (95 % CI) p-value (two-sided) Median (Q1, Q3) Median differenceanterior-posterior (95 % CI) p-value (two-sided)
VC [l] anterior 5.09 (3.98, 5.58) 0.38 (−0.15, 0.88) 0.167 3.98 (3.31, 4.67) 0.40 (−0.08, 0.88) 0.088
posterior 4.46 (3.90, 5.37) 3.46 (2.90, 4.34)
FEV1 [l/s] anterior 3.80 (3.34, 4.33) 0.25 (−0.16, 0.63) 0.174 3.05 (2.41, 3.44) 0.34 (−0.09, 0.72) 0.103
posterior 3.57 (3.01, 4.11) 2.58 (2.05, 3.22)
Sniff PmaxPeak [kPa] anterior 6.24 (4.84, 7.67) −0.24 (−1.24, 0.83) 0.655 5.13 (4.21, 7.22) −0.23 (−1.04, 0.56) 0.582
posterior 6.25 (5.09, 8.63) 5.70 (4.54, 6.83)