Skip to main content
. 2016 Apr 21;121(1):223–232. doi: 10.1152/japplphysiol.00545.2015

Table 7.

Correlations between airway tone and airway measurements

Asthma Health
Diameter baseline FRC r = −0.59, P = 0.008* P = 0.39
Diameter baseline TLC r = −0.72, P = 0.0005* P = 0.13
Diameter postalbuterol FRC P = 0.53 P = 0.16
Diameter postalbuterol TLC P = 0.15 P = 0.27
WT (frac dia) baseline FRC r = 0.70, P = 0.0012* P = 0.82
WT (frac dia) baseline TLC r = 0.85, P < 0.0001* P = 0.78
WT (frac dia) postalbuterol FRC P = 0.72 P = 0.81
WT (frac dia) postalbuterol TLC P = 0.11 P = 0.75
% Δ diameter FRC-TLC baseline r = −0.60, P = 0.007* r = −0.71, P = 0.03*
% Δ diameter FRC-TLC postalbuterol r = −0.49, P = 0.03* r = 0.21, P = 0.59

WT (frac dia), airway wall thickness expressed as a fraction of airway diameter.

*

P < 0.05.