Table 6.
Intra-day and inter-day accuracy and precision for determination of threohydrobupropion and erythrohydrobupropion β-d-glucuronide diastereomers in human urine with analyte specific calibration rangesa on an AB Sciex 4000 mass spectrometer.
| Intra-assay (n = 5) |
Inter-assay (n = 5) |
||||||
|---|---|---|---|---|---|---|---|
| Nominal concentration (ng/mL) |
Calculated Concentration (ng/mL)b |
Accuracy (%) | Precision (%) | Calculated concentration (ng/mL)b |
Accuracy (%) | Precision (%) | |
| (1S,2S) threohydrobupropion β-d-glucuronide | 100 | 98.0 ± 6.8 | 98 | 7 | 98.4 ± 4.0 | 98 | 4 |
| 250 | 254 ± 11 | 102 | 4 | 256 ± 18 | 102 | 7 | |
| 500 | 519 ± 48 | 104 | 9 | 547 ± 27 | 109 | 5 | |
| 1000 | 959 ± 67 | 96 | 7 | 973 ± 40 | 97 | 4 | |
| 2500 | 2604 ± 131 | 104 | 5 | 2563 ± 113 | 103 | 4 | |
| (1R,2R) threohydrobupropion β-d-glucuronide | 100 | 98.1 ± 7.8 | 98 | 8 | 100.4 ± 5.5 | 100 | 6 |
| 250 | 248 ± 16 | 99 | 6 | 252 ± 12 | 101 | 5 | |
| 500 | 495 ± 51 | 99 | 10 | 525 ± 30 | 105 | 6 | |
| 1000 | 986 ± 63 | 99 | 6 | 993 ± 60 | 99 | 6 | |
| 2500 | 2639 ± 132 | 106 | 5 | 2614 ± 78 | 105 | 3 | |
| (1R,2S) erythrohydrobupropion β-d-glucuronide | 100 | 99.3 ± 5.3 | 99 | 5 | 98.0 ± 4.4 | 98 | 4 |
| 250 | 245 ± 16 | 98 | 6 | 248 ± 15 | 99 | 6 | |
| 500 | 490 ± 42 | 98 | 9 | 508 ± 19 | 102 | 4 | |
| 1000 | 1040 ± 74 | 104 | 7 | 1054 ± 56 | 105 | 5 | |
| 2500 | 2570 ± 126 | 103 | 5 | 2537 ± 62 | 101 | 2 | |
Calibration ranges are provided in Table 1.
Mean ± standard deviation.