Table 2.
Rotational thromboelastometry variables derived from thromboelstometer graph
ROTEM variable | Description |
---|---|
CT: Clotting time (s) | Time until the recognizable start of clot formation (2 mm amplitude) |
CFT: Clot formation time (s) | Time until amplitude of 20 mm is reached. Represents the clot formation dynamics |
Angle: Alpha-angle (°) | Angle between central line and a tangent to the curve through the 2 mm amplitude point. Represents the kinetics of clot formation |
MCF: Maximum clot firmness (mm) | Maximum firmness (amplitude) that the clot achieves during the measurement |
A10-A30: Amplitude at 10-30 min after CT (mm) | Describes the clot firmness at 10-30 min after CT |
CL30: Clot lysis index at 30 min after CT (%) | Ratio between the MCF and the amplitude 30-60 min after CT. Describes the progress of fibrinolysis |