Skip to main content
. 2016 Jul;5(4):389–396. doi: 10.21037/acs.2016.07.08

Table 1. Anatomical requirements for ascending aortic TEVAR.

Proximal and distal landing zones
   Length >10 mm
   Diameter >16 and <42 mm
   No significant difference between proximal and distal landing zone (<10%)
   Absence of calcification or thrombotic material
Aortic dissection
   Intimal tear >10 mm above the sinotubular junction
   Intimal tear >5 mm proximal to the innominate artery
   No aortic regurgitation
Access vessels
   Diameter of the common and external iliac artery >7 mm

TEVAR, thoracic endovascular aortic repair.