Skip to main content
. 2016 Aug 5;6:30282. doi: 10.1038/srep30282

Table 2. Global fitting parameters of FCCS data at different Ykt6:DPC ratios.

Fittingparameter Ykt6:DPC = 1:0 Ykt6:DPC = 1:2
N 9.11 ± 0.53 8.87 ± 0.67
τD (μs) 220 ± 37 224 ± 7
τi (μs) 190 ± 55 15 ± 32
α 0.13 ± 0.04 0.04 ± 0.05
β 0.12 ± 0.05 0.07 ± 0.11
γ 1.01 × 10−4 ± 0.91 × 10−4 0.10 × 10−2 ± 0.88 × 10−2
δ 0.25 ± 0.06 0.15 ± 0.06

N is the average number of molecules in the focal region; τD is the average transit time through the focal area; τi represents the time constant for the dynamic among the correlations which is the intramolecular dynamic; parameters α and γ are scaling factors due to the correlation amplitudes; β and δ represent static contributions from FRET states. Compare the τi value between different ration of DPC, it shows that when the ratio increases to 1:2, the value of τi is in the range of the error bound of apo system.