Skip to main content
. 2015 Nov 12;88(1056):20150453. doi: 10.1259/bjr.20150453

Table 1.

Questionnaire sent to all IMPORT HIGH centres

Questions Answers
Volume delineation
Do you use titanium clip markers to guide whole breast radiotherapy planning (placement of whole breast treatment fields) for non trial patients with breast cancer? i) Yes
ii) No
If the answer is yes:
Before joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
After joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
Do you do any target volumes and organs at risk (OAR) contouring on non trial patients with breast cancer? i) Yes
ii) No
If the answer is yes:
Before joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
After joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
How do you do localise post-operative tumour bed for non trial patients with breast cancer in breast boost radiotherapy planning? Please choose all that apply. Before joining IMPORT HIGH
a) Clinical markup
b) CT only
c) CT with implanted markers
d) Others. Please specify
After joining IMPORT HIGH
a) Clinical markup
b) CT only
c) CT with implanted markers
d) Others. Please specify
Radiotherapy planning and treatment delivery
Do you use inverse planned or forward planned IMRT in IMPORT HIGH trial? i) Forward planned IMRT
ii) Inverse planned IMRT
For inverse planned IMRT centres, do you offer IMRT (either forward planned or inverse planned) to non trial patients with breast cancer? If yes, please specify the reasons. If the answer is inverse planned IMRT:
Before joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
After joining IMPORT HIGH
a) None
b) <50% of patients
c) ≥50% of patients
d) All patients
Do you use the IMPORT HIGH trial protocol for target volume and OAR dose constraints when you use IMRT for non-trial patients with breast cancer? i) Yes
ii) No
How is breast boost radiotherapy delivered for non trial patients with breast cancer at your centre? a) Single electron field
b) 3DCRT/IMRT photon treatment
If answer is 3DCRT/IMRT, did you implement this after joining IMPORT HIGH?
i) Yes
ii) No
Treatment verification
How do you perform treatment verification for non trial patients with breast cancer at your centre? a) Single MV/KV planar image at the tangential beam angles
b) 2D MV/KV image pairs
c) 3D MV/KV volumetric CT
d) Others. Please specify
What information do you use for breast radiotherapy verification for non trial patients with breast cancer at your centre? Please choose all that apply. a) Lung and heart depth measurement
b) Breast tissue/bony anatomy matching
c) Surgical clips/seeds matching
d) 3D volumetric tumour bed matching
Have you ever used implanted markers information to guide breast radiotherapy verification before joining IMPORT HIGH? i) Yes
ii) No
Do you use implanted markers information to guide breast radiotherapy verification for non trial patients with breast cancer after joining IMPORT HIGH? i) Yes
ii) No

3DCRT, three-dimensional conformal radiotherapy; IMRT, intensity-modulated radiotherapy; OAR, organs at risk.