Method Concentration/ABC NiDAB Comments
ABC–NiDAB 1 Most sensitive; strongest staining at lowest concentration
Direct tagged secondary antibody 20- to 100-fold higher concentration of primary antibody to get maximal staining Least sensitive of the fluorescence methods
ABC–streptavidin fluorescence 10- to 30-fold higher concentration of primary needed to obtain maximal staining Approximately 3 times more sensitive than the direct tagged secondary fluorescence
Biotinylated TSA-amplified streptavidin fluorescence 2-fold higher concentration of primary antibody yields equal sensitivity to the NiDAB method Most sensitive of the fluorescence methods