Table 1. An Example of Planning Dose Objective Input into the Auto-Planning for PTV-2 mm Plans .

ROI = region of interest; DVH = dose volume histogram; PTV = planning target volume, PRV = planning organ at risk volume

 

           ROI Type Dose (Gy) Vol (%) Priority Compromise
 PTV-2 mm Target 50      
2 mm_Ring Mean Dose 45   High Allow
5 mm_Ring Max  Dose 40   High Allow
2 cm_Ring Max  Dose 22   High Allow
Esophagus_2  mm PRV Max  Dose 40   High Allow
Esophagus_2  mm PRV Max  DVH 35 5% High Allow
Esophagus Max Dose 48   High Allow
Spinal Cord Max Dose 15   High Allow
Spinal Cord Max DVH 13 3% High Allow