Table 1. An Example of Planning Dose Objective Input into the Auto-Planning for PTV-2 mm Plans .
ROI = region of interest; DVH = dose volume histogram; PTV = planning target volume, PRV = planning organ at risk volume
ROI | Type | Dose (Gy) | Vol (%) | Priority | Compromise |
PTV-2 mm | Target | 50 | |||
2 mm_Ring | Mean Dose | 45 | High | Allow | |
5 mm_Ring | Max Dose | 40 | High | Allow | |
2 cm_Ring | Max Dose | 22 | High | Allow | |
Esophagus_2 mm PRV | Max Dose | 40 | High | Allow | |
Esophagus_2 mm PRV | Max DVH | 35 | 5% | High | Allow |
Esophagus | Max Dose | 48 | High | Allow | |
Spinal Cord | Max Dose | 15 | High | Allow | |
Spinal Cord | Max DVH | 13 | 3% | High | Allow |