Table 2.
Values % Ea/Em, EC50, and pEC50 for AVP determined after ischemia and reperfusion in the presence of 8Br-cGMP.
| % Ea/Em | EC50 | pEC50 | |
|---|---|---|---|
| Control | 100,00 | 9,696 × 10−7 | 7,987 |
| AVP + 8Br-cGMP | 79,29 | 3,865 × 10−7 ∗ | 7,587a |
| Ischemia + 8Br-cGMP | 21,03 | 3,492 × 10−6 ∗∗ | 6,543b |
| Reperfusion 30′ + 8Br-cGMP | 117,70 | 7,583 × 10−8 † | 8,880c |
| Reperfusion 90′ + 8Br-cGMP | 147,70 | 2,559 × 10−9 †† | 9,408d |
EC50 control versus EC50 ∗/∗∗/†/††, p < 0.05; pEC50 control versus pEC50 b/c/d, p < 0.05; pEC50 control versus pEC50 a, p = ns.
% Ea/Em: % of maximum reaction.
EC50: concentration triggering 50% of the maximum reaction.
pEC50: −log 10 of EC50.