Table 2.
Offset (%) | tau | n | |
---|---|---|---|
−70mV Control | 0.3 ± 0.2 | 31.9 ± 1.1 | 4 |
−70mV FGF13S | 33.4 ± 0.1** | 84.4 ± 11** | 4 |
−70mV FGF13U | 40.9 ± 0.2** | 95.4 ± 7.6** | 4 |
−70mV FGF13VY | 26.3 ± 0.2 ** | 73.1 ± 7.3** | 4 |
−90mV Control | 42.7 ± 3 | 69.3 ± 11.8 | 4 |
−90mV FGF13S | 83 ± 8.7** | 164.9 ± 12.3** | 4 |
−90mV FGF13U | 90.8 ± 5.4** | 153.3 ± 12.9** | 4 |
−90mV FGF13VY | 73.2 ± 10.2 ** | 268.1 ± 28.4** | 4 |
Offset is the proportion of current that did not inactivate.
P < 0.01 compared to control at the same voltage.