Skip to main content
. 2016 Aug 16;9(8):e005030. doi: 10.1161/CIRCIMAGING.116.005030

Figure 5.

Figure 5.

Length of mitral annular disjunction (MAD) in sudden cardiac death (SCD) patients: controls vs mitral valve prolapse (MVP) patients. The length of MAD (measured as micrometers) in SCD patients with MVP is significantly higher than in controls (A). Representative histology of the mitral annulus showing the absence of MAD in a SCD control (B) as compared with an elongated MAD in a SCD patients with MVP (C).