Skip to main content
. 2010 Sep 15;3(3):153–161. doi: 10.5005/jp-journals-10005-1071

Table 1: Descriptive statistics on the microleakage pattern of Filtek™ Flow following immersion for varying periods of time in Cola drink (Coca Cola®), Fresh fruit juice (Orange) and Water (Control)

Groups     Microleakage
scores    
Low
immersion    
Medium
immersion    
High immersion     Difference between Immersion
regime    
     No     Mean
median    
No     Mean
median    
No     Mean
median    
Low vs
medium    
Low vs
high    
Medium vs
high    
Group I -
Cola drink
(Coca
Cola®)    
0     4     0.6
1.0    
-     2.0
2.0    
-     2.8
3.0    
P< 0.001
HS    
P< 0.001
HS    
P< 0.001
HS    
1     6     -     -    
2     -     10     2    
3     -          8    
Group II -
Fresh fruit
juice
(Orange)    
0     10     0.0
0.0    
7     0.3
0.0    
1     0.9
1.0    
P> 0.005
NS    
P< 0.001
HS    
P< 0.001
S    
1     -     3     9    
2     -     -     -    
3     -     -         
Group III -
Water
(Control)    
No immersion regime was followed    
0     10     0.0
0.0    
    
1     -    
2     -    
3     -    
Differences
between
groups    
Group I - II     P<0.01 s     p < 0.001 HS     P< 0.001 HS         
Group I - III     P<0.01 s     p < 0.001 HS     P< 0.001 HS    
Group II - III     p > 0.05 NS     p>0.05 NS     P< 0.001 HS    

Chi-square test/Fisher’s exact test