. 2016 Aug 22;16(1):31. doi: 10.1186/s12873-016-0095-0

Table 2.

Overall performance characteristics

Alert Cutoff sens fpr auc spec ppv npv FP/Day Inc. Sepsis TP
Nurse Other
Triangle Nurse 1.000 54.3 % 3.1 % 0.756 96.9 % 6.1 % 99.8 % 6.44
SIRS Derived 1.000 21.6 % 0.4 % 0.606 99.6 % 17.2 % 99.7 % 0.80 187 4
Cut05 0.050 76.4 % 4.7 % 0.859 95.3 % 5.8 % 99.9 % 9.64 22 100
Cut04 0.040 79.0 % 5.4 % 0.868 94.6 % 5.2 % 99.9 % 11.16 18 105
Sens80 0.036 80.1 % 5.8 % 0.871 94.2 % 4.9 % 99.9 % 12.03 17 108
FPC15 0.026 85.2 % 7.3 % 0.890 92.7 % 4.2 % 99.9 % 15.00 13 122
MaxAUC 0.017 89.2 % 9.9 % 0.897 90.1 % 3.3 % 100.0 % 20.33 % 12 135
NrsFP 0.097 70.2 % 3.1 % 0.835 96.9 % 7.8 % 99.9 % 6.44 32 88
NrsSens 0.330 54.3 % 1.6 % 0.763 98.4 % 11.4 % 99.8 % 3.27 64 64

SIRS systemic inflammatory response syndrome, Cut05/Cut04 Bayesian cutpoint threshold of 0.05/0.04, Sens80 threshold for sensitivity = 80 %, FPC15 threshold of 15 false positive alerts per day, MaxAUC threshold maximizing area under the receiver operating characteristic curve, NrsFP nurse-driven false positive threshold, NrsSens nurse-driven sensitivity threshold. Boldface indicates the primary cutpoint used