Table 1. Comparison of the performance for compounds 1 to 11 by cyclic voltammetry testsa.

No. MWb E10(V)c E20(V)c ipa/ipcd Acceptable?
1 138 no
2 338 3.94 1.07 yes
3 194 no
4 180 4.07 2.11 no
5 166 4.10 4.26 no
6 166 3.92 1.04 yes
7 166 3.98 1.08 yes
8 152 3.96 4.14 no
9 196 4.30 1.46 no
10 183 4.48 1.33 no
11 156 4.17 4.35 no

a1 M LiTFSI in EC/PC/EMC (4:1:5 by weight);

bMolecular weight in a.m.u.;

cThe first and second redox potentials vs. Li/Li+;

dThe ratio of the anodic and cathodic peak currents at the voltage scan rate of 10 mV/s.