Demographic information of liner hosts (revision and postmortem).

Implant source (N) Gender (N) Side (N) In situ time (mo.) Cause of failure (N)
Revisions (54) Females (22)
Males (26)
Unknown (6)
Left (24)
Right (23)
Unknown (7)
Range (1–108)
Mean (26)
Unknown (16)
Infection (10)
Maltracking (9)
Loose (9)
Instability (5)
Synovitis (2)
Fracture (1)
Osteolysis (1)
Failed liner (1)
PE wear∗∗ (1)
Unknown (15)

Postmortem (21) Females (13)
Males (8)
Left (11)
Right (10)
Range (19–144)
Mean (79)
Autopsy (21)

Simulator (6) Not applicable Left (6) 60 months Not applicable

Heavily delaminated (10) Females (5)
Males (4)
Unknown (1)
Left (7)
Right (3)
Range (24–130)
Mean (73)
Unknown (3)
Instability (2)
Polyethylene wear (2)
Tibial subsidence (2)
Painful tibial component (1)
Unknown (3)