Skip to main content
BMC Anesthesiology logoLink to BMC Anesthesiology
. 2016 Aug 31;16:72. doi: 10.1186/s12871-016-0238-6

Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis

Kyu Nam Kim 1, Dong Won Kim 1,, Mi Ae Jeong 1, Yeong Hun Sin 1, Soo Kyung Lee 1
PMCID: PMC5007729  PMID: 27581657

Abstract

Background

Not only arterial hypoxemia but acute lung injury also has become the major concerns of one-lung ventilation (OLV). The use of pressure-controlled ventilation (PCV) for OLV offers the potential advantages of lower airway pressure and intrapulmonary shunt, which result in a reduced risk of barotrauma and improved oxygenation, respectively.

Methods

We searched Medline, Embase, the Cochrane central register of controlled trials and KoreaMedto find publications comparing the effects of PCV with those of volume-controlled ventilation (VCV) during intraoperative OLV in adults. A meta-analysis of randomized controlled trials was performed using the Cochrane Review Methods.

Results

Six studies (259 participants) were included. The PaO2/FiO2 ratio in PCV was higher than in VCV [weighted mean difference (WMD) = 11.04 mmHg, 95 % confidence interval (CI) = 0.30 to 21.77, P = 0.04, I2 = 3 %] and peak inspiratory pressure was significantly lower in PCV (WMD = −4.91 cm H2O, 95 % CI = −7.30 to –2.53, P < 0.0001, I 2 = 91 %). No differences in PaCO2, tidal volume, heart rate and blood pressure were observed. There were also no differences incompliance, plateau and mean airway pressure.

Conclusions

Our meta-analysis provided the evidence of improved oxygenation in PCV. However, it is difficult to draw any definitive conclusions due to the fact that the duration of ventilation in the studies reviewed was insufficient to reveal clinically relevant benefits or disadvantages of PCV. Significantly lower peak inspiratory pressure is the advantage of PCV.

Electronic supplementary material

The online version of this article (doi:10.1186/s12871-016-0238-6) contains supplementary material, which is available to authorized users.

Keyword: One-Lung Ventilation; Respiration, artificial

Background

One-lung ventilation (OLV) is necessary to facilitate surgical access or to isolate a lung during thoracic surgery procedure. During OLV, the intentionally collapsed lung,which is continuously perfused but not ventilated, develops an intrapulmonary shunt leading to arterial hypoxemia [1, 2]. Although arterial hypoxemia is still a critical intraoperative problem, avoidance of lung injury has become the major concern in OLV [3, 4]. Elevated airway pressure associated with mechanical ventilation is the important risk factor for ventilator-induced lung injury [5, 6]. In addition, inflammatory reactions and tissue injuries associated with lung re-expansion cause the ventilator-induced lung injury after OLV [710].

The ventilator settings, including tidal volume and positive end-expiratory pressure (PEEP), for OLV were generally the same as for two-lung ventilation (TLV) previously [11]. However, the use of the conventional large tidal volume has been identified as a major risk factor for ventilator-induced lung injury [12, 13]. Therefore, the current trend is towards the use of low tidal volumes (4–6 ml/kg) instead of large tidal volumes (10–12 ml/kg) for OLV [14, 15]. The use of pressure-controlled ventilation (PCV) for OLV is seen as an alternative ventilator mode aimed at avoiding high airway pressure. When OLV is started, the entire tidal volume is delivered to just one lung, resulting in increased airway pressure in that lung. Because of the possibility of ventilator-induced lung injury when applying volume-controlled ventilation (VCV), a preference for applying PCV has developed [16].

During OLV, PCV offers the advantages of lower airway pressure and a lower intrapulmonary shunt leading to a reduced risk of ventilator-induced lung injury and improved oxygenation, respectively [1719]. However, others have reported that PCV results in poorer oxygenation [20, 21] and the effect of PCV on oxygenation is one of the areasof greatest controversy. We hypothesized that PCV is associated with improved oxygenation and lower inspiratory pressure in comparison with VCV. Therefore, the authors have performed a systematic review and meta-analysis comparing the effect of PCV with that of VCV during intraoperative OLV in adults.

Methods

We used a systematic approach to find publications comparing pressure-controlled ventilation with volume-controlled ventilation during OLV. This study is based on the Cochrane Review Methods [22].

Data sources& literature sources

We searched Medline, Embase, the Cochrane central register of controlled trials and KoreaMed for eligible studies from inauguration to 22 July 2014, using a combination of controlled vocabulary (MeSH, Emtree) and free text terms. Main keywords were OLV, PCV and VCV. Search strategies were modified suitably for each database (Additional file 1). We manually searched the reference lists of the retrieved studies, ClinicalTrials.gov and the WHO ICTRP for additional unpublished/published studies.

Study selection

All the studies selected were independently identified by two reviewers (KNK and MAJ) based on predefined selection criteria. We screened the titles and abstracts of the identified studies and then screened the full textsof the studies marked for inclusion. Disagreement in the primary study selection was arbitrated by the third reviewer (DWK). Studies were included in our meta-analysis if they fulfilled the following criteria: (1) Literature type: randomized controlled trials in all published international journals without limitation of language or nationality. (2) Subjects: adult patients undergoing elective surgery requiring OLV. (3) Interventions: studies comparing the effect of PCV with VCV during OLV. (3) Outcomes: the primary outcome was the PaO2/FiO2 ratio, and secondary outcomeswere peak, plateau, and mean inspiratory airway pressures and postoperative events. Other parameters of gas exchange, including PaO2, SaO2, PaCO2, alveolar-arterial oxygen difference, intrapulmonary shunt were also collected. The outcome variables are mean differences between the groups at the designated times.

Data extraction

Two reviewers (KNK and MAJ) independently extracted the data using a pre-specified data extraction form. The data extracted from the selected studies was confirmed by the third reviewer (DWK).

The following variables were extracted: (1) means and standard deviations of the outcome data in the PCV and VCV groups; (2) number of patients, type of surgery, and recruitment procedure for each group; (3) the protocol for using fraction of inspired oxygen during surgery, and ventilator settings such as tidal volume, respiratory rate, inspiratory/expiratory ratio, inspiratory pause and PEEP for each group; (4) the timepoint of measurement of outcome data and (5) the method of assessment. If the above variables were not mentioned in a study, we asked for the data via email.

Assessment of methodological quality

The reviewer (KNK and MAJ) independently assessed the risk of bias in each study using the Cochrane risk of bias tool. This tool assesses randomized controlled trials by evaluating the reported methods for random sequence generation, concealment of allocations, blinding of participants, personnel and the outcome assessor, incompleteness of outcome data, selective outcome reporting, and other possible sources of risk of bias. Discrepancies between the two reviewers were resolved face-to-face.

Statistical analysis

The continuous variables such as PaO2/FiO2 ratio, intrapulmonary shunt and airway pressure were obtained at designated times. We analyzed the continuous data using weighted mean differences (WMD) employing the generic inverse variance method, and reported mean differences and their associated 95 % confidence intervals (CI). Heterogeneity between studies was assessed using the χ2 test and the I2 statistic [23]. We considered that an I2 statistic >50 % and aχ2 test with a P value <0.10 indicated statistical heterogeneity. We used random-effects models if clinical heterogeneity or statistical heterogeneity were detected. A subgroup analysis was performed to eliminate the effect of paravertebral block which has an effect of sympathetic nervous system blockade that inhibits hypoxic pulmonary vasoconstriction (HPV). A subgroup analysis between low tidal volume (6–8 ml/kg) and high tidal volume (9–10 ml/kg) was also performed because the reduction of tidal volume to 6–8 ml/kg was beneficial in terms of occurrence of respiratory complications and the length of hospital stay [24].

In meta-analyses that include the results of cross-over studies (in which patients cross over from one treatment to another during the course of the trial), there is a risk of bias due toa carry-over effects [25]. We conducted a sensitivity analysis in situations where this could affect our estimates.

All statistical analyses were conducted using RevMan version 5.2. When the number of studies included was less than 10, we did not evaluate publication bias because of the low statistical power.

Results

Identification of studies

Initial searches of the databases yielded 2791 articles. After removing 1014 duplicated articles, 1755 further publications were eliminated as it wasclear from their titles and abstracts that they did not fulfill the selection criteria. For the remaining 22 articles, we obtained full manuscripts, and, following scrutiny of these, identified six articles describing potentially relevant studies; the 16 others were excluded because of use of a different mode of ventilation (five articles), two abstracts, no available outcome data (four articles), study design not randomized (one article), andthe same study data reported twice (one article). One article was excluded because of thoracotomies for robotic-assisted esophagectomy with prone position and twoarticles were excluded to remove variables that might affect oxygenation because cardiopulmonary bypass influences HPV and oxygenation. Hence, six studies [18, 21, 2629] and 259 participants were included in this review (Fig. 1).

Fig. 1.

Fig. 1

Flow-chart of the literature search strategy

Study characteristics and patient populations

The included articles were published in four countries: South America, Saudi Arabia, Spain (2), and Turkey (2) between 1997 and 2014. The patients in six studies [18, 21, 2629] underwent thoracotomies for lung operations such as pneumectomy, lobectomy and wedge resection. The operating position in all cases was lateral decubitus. Each study used the same FiO2 and ventilator settings throughout each OLV. Five were crossover studies [18, 21, 2729] which applied PCV for 30 min followed by VCV, in one experimental group, and the reverse order in the other. The patients were allocated randomly to one of the two groups and all measurements were made 30 min after starting each ventilation mode. One study [26] was non-crossover study (Table 1).

Table 1.

The characteristics of the included randomized controlled trials comparing pressure-controlled ventilation with volume-controlled ventilation

Ventilator settings
Study and year ASA Patients (n) Surgery Tidal Volume Target CO2 I:E ratio Inspiratory pause FiO2 PEEP (cmH2O) RM Timing of RM
PCV VCV Kg
Al Shehri [29] 2014 II-III PCV-VCV 14 Thoracotomy for lung disease 6 ml/kg 6 ml/kg PBW PaCO235-45 mmHg 1:2.5 N/D 0.5 5 Yes At every 30 min
VCV-PCV 14
ErenOngur [27] 2010 I-II PCV-VCV 15 Thoracotomy for lung disease 6–7 ml/kg 6 –7 ml/kg TBW PaCO235 –45 mmHg N/D N/D 0.5 0 Yes Before returning to TLV
VCV-PCV 15
Montes [21] 2010 I-III PCV-VCV 21 Thoracotomy for lung disease 6 ml/kg 6 ml/kg TBW ETCO225 –30 mmHg 1:3 10% 1.0 5 No
VCV-PCV 20
Pardos [26] 2009 N/D PCV 55 Thoracotomy for lung disease 8 ml/kg 8 ml/kg TBW PaCO235 –40 mmHg 1:2 15% 1.0 5 Yes At 20 min after OLV
VCV 55
Tugrul M [18] 1997 I-III PCV-VCV 24 Thoracotomy for lung disease 10 ml/kg 10 ml/kg TBW PaCO234 –45 mmHg 1:3 10% 1.0 0 No
VCV-PCV 24
Unzueta MC [28] 2007 II-III PCV-VCV 29 Thoracotomy for lung disease 9 ml/kg 9 ml/kg TBW ETCO230 –35 mmHg 1:2 0.9 s 1.0 0 No
VCV-PCV 28

The respiratory rate was adjusted to maintain PaCO2 or ETCO2

ASA American Society of Anesthesiologists’ classification, (n) number of cases, PCV pressure-controlled ventilation, VCV, volume-controlled ventilation, I:E ratio the inspiratory to expiratory time ratio, FiO 2 fraction of inspired oxygen, PEEP positive end-expiratory pressure, RM recruitment maneuver, PBW predicted body weight, PaCO 2 partial pressure of carbon dioxide, ETCO 2 end-tidal carbon dioxide, TLV two-lung ventilation, OLV one-lung ventilati on, N/D no data

Quality of the included studies

All the studies used a random allocation method and one study [29] described the allocation concealment and blinding methods in detail. Although the risk of selective reporting and incomplete outcome data was low, the risk of allocation concealment and blinding was unclear in most studies. Risk-of-bias graphs and summaries are presented in Fig. 2a and b.

Fig. 2.

Fig. 2

a Risk-of-bias graph of all the included randomized controlled trials. b Risk-of-bias summary of all the included randomized controlled trials

Statistical heterogeneity

PaO2/FiO2 ratio, PaCO2, tidal volume, heart rate and blood pressure showed no significant heterogeneity among the studies (I2 statistic value < 40 %). Those of peak, plateau, and mean inspiratory airway pressure and compliance displayed heterogeneity (I2 statistic value > 60 %).

Gas exchange

The PaO2/FiO2 ratio was extracted from 6 randomized trials [18, 21, 2629]. We found a higher PaO2/FiO2 ratio in PCV than in VCV (WMD = 11.04 mmHg, 95 % CI = 0.30 to 21.77, P = 0.04) (Fig. 3a), but they did not differ in PaCO2 (WMD = −0.28 mmHg, 95 % CI = −1.14 to 0.58, P = 0.52) (Fig. 3b).

Fig. 3.

Fig. 3

Meta-analysis of the effect of intraoperative ventilation with pressure-controlled ventilation compared with volume-controlled ventilation. a Impact on PaO2/FiO2 ratio (mmHg). b Impact on PaCO2 (mmHg)

Airway pressure and compliance

Peak inspiratory pressure was significantly lower in PCV (WMD = −4.91 cmH2O, 95 % CI = −7.30 to –2.53, P < 0.0001) (Fig. 4a). However, there were no differences in plateau (WMD = −1.13 cmH2O, 95 % CI = −2.54 to 0.28, P = 0.12) (Fig. 4b), mean airway pressure (WMD = 0.08 cmH2O, 95 % CI = −0.38 to 0.54, P = 0.74) (Fig. 4c) or compliance (WMD = 2.89 ml/cmH2O, 95 % CI = −1.69 to 7.46, P = 0.22) (Fig. 4d).

Fig. 4.

Fig. 4

Meta-analysis of the effect of intraoperative ventilation with pressure-controlled ventilation compared to volume-controlled ventilation. a Impact on peak airway pressure (cmH2O). b Impact on plateau airway pressure (cmH2O). c Impact on mean airway pressure (cmH2O). d Impact on compliance (ml/cmH2O)

Tidal volume and hemodynamic variables

Tidal volume which was measured in each ventilator mode was reported in 3studies [18, 21, 28]. There was no difference in tidal volume between PCV and VCV (WMD = 0.83 ml, 95 % CI = −21.89 to 21.59, P = 0.99) during OLV. There were also no differences in heart rate (WMD = −0.70 beat/min, 95 % CI = −3.47 to 2.07, P = 0.62) or blood pressure (WMD = −0.43 mmHg, 95 % CI = −3.94 to 3.09, P = 0.81).

Postoperative events

Postoperative events were reported in two studies [26, 29]. The length of postoperative stay and development of lung injury/adult respiratory distress syndrome (ARDS) were not different between groups. Mortality within 30 days was not observed in both groups.

Subgroup analysis

A subgroup analysis including the studies in which paravertebral blockwas not performed showed that PCV was more effective than VCV with respect to the PaO2/FiO2ratio (WMD = 19.51 mmHg, 95 % CI = 5.77 to 33.25, P = 0.005) (Fig. 5a). However, paravertebral block with PCV showed no difference in PaCO2(WMD = −0.35 mmHg, 95 % CI = −1.30 to 0.61, P = 0.48) (Fig. 5b). The studies which applied low tidal volume (6–8 ml/kg) with PCV had the higher PaO2/FiO2 ratio than low tidal volume (6–8 ml/kg) with VCV in our subgroup analysis (WMD = 14.73 mmHg, 95 % CI = 1.92 to 27.55, P = 0.02) (Fig. 5c).

Fig. 5.

Fig. 5

Subgroup analysis during pressure-controlled ventilation compared to volume-controlled ventilation. a The effect of paravertebral block on PaO2/FiO2 ratio (mmHg). b The effect of paravertebral block on PaCO2 (mmHg). c The effect of tidal volume (6–8 ml/kg vs 9–10 ml/kg) on PaO2/FiO2 ratio

Sensitivity analysis

We performeda sensitivity analysis to evaluate the influence of the crossover study design. The results for 5 crossover studies [18, 21, 2729] showed an increased PaO2/FiO2 ratio in PCV (WMD = 12.84 mmHg, 95 % CI = 1.21 to 24.47, P = 0.03). A minor increase in mean airway pressure in PCV (WMD = 0.70 mmHg, 95 % CI = 0.11 to 1.29, P = 0.02) was detected in the analysis of one non-crossover study [26]. The sensitivity analysis of the crossover study design did not affect the resultsfor PaCO2 and peak and plateau airway pressure (Table 2).

Table 2.

Sensitivity analysis of crossover study and abstract on the meta-analysis

Outcome Studies (n) Patients (n) WMD 95 % CI I2 (%) P value
PaO2/FiO2 ratio Total 6 [18, 21, 2629] 259 11.04 mmHg 0.30 to 21.77 3 0.04
Crossover studies 5 [18, 21, 2729] 204 12.84 mmHg 1.21 to 24.47 12 0.03
Non-crossover studies 1 [26] 55 0.70 mmHg −27.15 to 28.55 0 0.96
PaCO2 Total 5 [18, 21, 26, 28, 29] 229 −0.28 mmHg −1.14 to 0.58 0 0.52
Crossover studies 4 [18, 21, 28, 29] 174 −0.32 mmHg −1.22 to 0.58 0 0.49
Non-crossover studies 1 [26] 55 0.10 mmHg −2.71 to 2.91 65 0.94
Peak inspiratory
Pressure
Total 6 [18, 21, 2629] 259 −4.91cmH2O −7.30 to −2.53 91 <0.0001
Crossover studies 5 [18, 21, 2729] 204 −5.27cmH2O −7.98 to −2.57 92 <0.0001
Non-crossover studies 1 [26] 55 −3.10cmH2O −4.79 to −1.41 0 <0.0001
Plateau inspiratory
Pressure
Total 5 [18, 21, 26, 28, 29] 229 −1.13cmH2O −2.54 to 0.28 80 0.12
Crossover studies 4 [18, 21, 28, 29] 174 −1.44cmH2O −3.06 to 0.18 83 0.08
Non-crossover studies 1 [26] 55 0.20cmH2O −1.49 to 1.89 0 0.82
Mean inspiratory Pressure Total 4 [18, 21, 26, 28] 201 0.08cmH2O −0.38 to 0.54 60 0.74
Crossover studies 3 [18, 21, 28] 146 −0.15cmH2O −0.48 to 0.18 0 0.38
Non-crossover studies 1 [26] 55 0.70cmH2O 0.11 to 1.29 0 0.02

(n) the number of cases, WMD weighted mean difference, CI confidence interval, PCV pressure-controlled ventilation, VCV volume-controlled ventilation, PaO 2 partial pressure of oxygen, FiO 2 fraction of inspired oxygen, PaCO 2 partial pressure of carbon dioxide

Discussion

Many studies have been performed in animals and humansto discover the most effective and safe ventilator strategies for OLV, and PCV has been recognized as a suitable method. PCV generates a square pressure waveform (constant inspired flow), which is results by the high delivering flow into the ventilator circuit. Theoretically, a decelerating inspiratory flow pattern results in a more even distribution of tidal volume, facilitating recruitment of insufficiently ventilated lung units and improvingoxygenation [3033]. In addition, the rapid alveolar inflation caused by the high initial flow rate in PCV avoids regional overdistension because of the homogeneous gas distribution, and enables better ventilation perfusion matching [34]. Although the difference is minimal, PCV is more effective than VCV in oxygenation and significantly lower peak inspiratory pressure in PCV was observed in this meta-analysis.

Despite the aforementioned benefits of PCV, the magnitude of the increase in PaO2/FiO2 ratio in PCV was quite limited. There are several explanations for this result. First, PCV tends to produce a higher mean airway and alveolar pressure than VCV because of the rapid delivery of most of the tidal volume in the early part of inspiration [32], and in passive inflation conditions mean airway pressure closely correlates with alveolar ventilation, arterial oxygenation and cardiovascular function [35]. As a result, the increased mean airway pressure in PCV is associated with improved oxygenation. However,the fact that there was no difference in mean airway pressure between the two groups in this meta-analysis demonstrates the weakness of the effect of PCV on oxygenation during OLV. In the absence of recruitment, compression of the intra-alveolar vessels due to the high mean airway pressure during inflation rather increases the intrapulmonary shunt [32].

Other reason could be the lack of PEEP and the use of a recruitment maneuver which was applied only in three studies [21, 26, 29] and 2 studies [26, 29], respectively. PCV with PEEP is associated with an improvement in oxygenation and providing lower airway pressure during OLV [17]. In addition, alveolar recruitment strategies decrease alveolar dead space and improve gas exchange during OLV [17, 36, 37]. These effects of PEEP and recruitment maneuvers during OLV may encourage the recruitment of insufficiently ventilated lungs,and this could be facilitated by the decelerating inspiratory flow pattern of PCV.

Lastly, PCV per se may have no clinical benefits in terms of improving oxygenation. In studies of ARDS, there was no significant effect of PCV on gas exchange [34, 38, 39]. The results of one experimental study even suggest that the high initial flow rates of PCV cause lung tissue injury and reduce gas exchange rather than protecting the lung [40].

Another interesting issue raised by this meta-analysis is how HPV influences the effect of PCV on oxygenation. The subgroup analysis performed to eliminate the effect of paravertebral block showed that the PaO2/FiO2 ratiowas better in PCV than VCV. The intrapulmonary shunt occurring during OLV could be compensated for by the blood flow diverted to the ventilated lung by HPV [41]. Paravertebral block with local anesthetics has an effect of sympathetic nervous system blockade that inhibits HPV and thereby produces a larger shunt and a decrease in oxygenation during OLV [4244]. Based on these results, it appears that the larger shunt due to the inhibition of HPV reduces the favorable effects of PCV in improving oxygenation.

Although we detected a significantly reduced peak inspiratory pressure in PCV in our meta-analysis, this difference in peak inspiratory pressure did not constitute a specific advantage of PCV, according to our meta-analysis. Since the airway pressure caused by resistance factors is dependent on flow during ventilatory delivery of tidal volume, airway pressure and alveolar pressure are identical only when there is no flow [45]. Thus, peak inspiratory pressure which was measured while high inspiratory gas flow occurred could not reflect alveolar pressure precisely. Furthermore, the incidence of barotrauma is strongly correlated with plateau airway pressure rather than peak inspiratory pressure, and to avoid overinflation of the ventilated lung during OLV, < 35 cmH2O of peak inspiratory pressure and < 25 cmH2O of plateau airway pressure are recommended [46, 47]. Plateau airway pressure of < 30 cmH2O probably does not deteriorate the development of lung injury/ARDS after OLV [4, 15]. Because both the peak and plateau pressures werebelow these limits in all the studies included in this meta-analysis, and no difference in plateau airway pressure was detected between the two groups, no clinical merit of PCV was found despite the lower peak inspiratory pressure in PCV.

In addition, as we mentioned before, the focus of mechanical ventilation has moved to prevent the development of lung injury. However, few studies have been performed to evaluate postoperative lung complications after OLV using different ventilator modes. Although we found no differences in the length of postoperative stay, development of lung injury/ARDS and mortality within 30 days between the two groups, it is not reasonable to draw any conclusions about the effectiveness of different ventilator modes from only two studies.

In the ways that both OLV and ARDS are ventilated with a small lung volume,the so-called baby lung in ARDS and one lung in OLV, OLV is similar to ARDS [3]. Hence, reducing the tidal volume, which is a protective ventilation strategy in ARDS,may also be protective in the case of OLV. Michelet et al. reported that a protective ventilation strategy group, ventilated with a tidal volume of 5 ml/kg and PEEP of 5 cmH2O during OLV developed lower proinflammatory systemic responses (IL-1β,IL-6 and IL-8), and had improved lung function and earlier extubation [48]. Licker et al., have reported clinical benefits of low tidal volumefrom the secondary analysis of an observational cohort [49]. The use of a low tidal volume with PEEP and recruitment maneuvers during OLV significantly reduced the incidence of lung injury and atelectasis after lung cancer resection. Our subgroup analysis also revealed that the studies which applied low tidal volume (6–8 ml/kg) with PCV had the higher PaO2/FiO2 ratio than low tidal volume (6–8 ml/kg) with VCV (Fig. 5c). Nevertheless, only few studies which have been reported were using low tidal volume of 6–8 ml/kg for OLV. Because the adverse effects of ventilation with a high tidal volume can exacerbate lung injury, the beneficial effects of PCV may be too weak to be detected. Therefore, well-controlled randomized studies using a low tidal volume in each ventilator mode during OLV are needed to accurately assess differences between PCV and VCV.

Limitations of our study

Our meta-analysis has several limitations. First of all, the relatively small number of patients was included in this study. Intervention effects can be significantly over stated in small trials with incomplete allocation sequence generation, allocation concealment, and double blinding [50]. However the patients in all the studies in the meta-analysis had been randomly allocated and the outcome data for mechanical ventilation involved objective measurements. Consequently, we believe that the risk of bias in these studies was low and the intervention effects were properly estimated.

Secondly, most of the studies included in it are crossover studies, and it could be agreed that the analysis has a problem with reliability. Crossover studies have the problem of carryover effects that may affect the analysis of interventions. However, PaO2 was maintained after 20 min of ventilation [51] and ventilation for more than 20 min can washout the influence of previous ventilator settings. Therefore the fact that all the outcome data of our crossover studies were obtained after 30 min of ventilation may have eliminated any carryover effects. Furthermore, the crossover study design has the advantage of reducing the effect of individual differences in terms of age, pulmonary function and severity of disease, which can lead to misinterpretation of the results. According to our sensitivity analysis of the crossover studies, gas exchange was more efficient in PCV (Table 2). This may have been due toan underestimation of the effect of PCV in the non-crossover studies due to individual factors. Nevertheless, owing to the slight effect on gas exchange of PCV in comparison with VCV, the clinical significance of this difference is small. Furthermore, there still remains the problem that the 30 min of temporary ventilation was not sufficient to reveal clinically-relevant benefits or adverse effects of PCV.

Lastly, evaluating the postoperative pulmonary complications after OLV using different ventilator modes is important to assess whether PCV could lower the theoretical risk of ventilator-induced lung injury. However, few studies have been performed to evaluate postoperative lung complications after OLV.

Conclusions

In conclusion, our meta-analysis has provided evidence that peak inspiratory pressure is significantly lower in PCV. In terms of oxygenation, although the use of low tidal volume with PCV was associated with improved oxygenation, no definitive conclusions could be drawn because the duration of ventilation in the studies reviewed was insufficient to rule out important differences if they exist. Most of the studies included in the meta-analysis were crossover studies involving 30 min of ventilation, and used high tidal volumes that are risk factors for lung injury. Therefore, to evaluate the influence of PCV on occurrence of the lung injury/ARDS, well-controlled randomized non-crossover studies using low tidal volumes with adequate durations of each ventilator mode, are needed.

Acknowledgements

Not applicable.

Funding

This study was not supported by external funding.

Availability of data and material

All relevant data and materials are presented in the manuscript.

Authors’ contributions

KNK: study design, study selection, data extraction, assessment of methodological quality, analysis and interpretation of data and writing of the article; DWK: study design, study selection, data extraction, assessment of methodological quality, analysis and interpretation of data and writing of the article; MAJ: study selection, data extraction and analysis, assessment of methodological quality, and interpretation of data; YHS: analysis and interpretation of data; SKL: analysis and interpretation of data and writing of the article. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Not applicable.

Abbreviations

ARDS

Adult respiratory distress syndrome

CI

Confidence intervals

HPV

Hypoxic pulmonary vasoconstriction

OLV

One-lung ventilation

PCV

Pressure-controlled ventilation

PEEP

Positive end-expiratory pressure

TLV

Two-lung ventilation

VCV

Volume-controlled ventilation

WMD

Weighted mean difference

Additional file

Additional file 1: Table S1. (23.5KB, docx)

Search strategies of each database. (DOCX 23 kb)

Footnotes

Electronic supplementary material

The online version of this article (doi:10.1186/s12871-016-0238-6) contains supplementary material, which is available to authorized users.

Contributor Information

Kyu Nam Kim, Email: vesicle100@naver.com.

Dong Won Kim, Phone: 82-2-2290-8680, Email: dongwkim@hanyang.ac.kr.

Mi Ae Jeong, Email: macheong@hanyang.ac.kr.

Yeong Hun Sin, Email: willy9443@naver.com.

Soo Kyung Lee, Email: sookyung0204@gmail.com.

References

  • 1.Karzai W, Schwarzkopf K. Hypoxemia during one-lung ventilation: prediction, prevention, and treatment. Anesthesiology. 2009;110:1402–1411. doi: 10.1097/ALN.0b013e31819fb15d. [DOI] [PubMed] [Google Scholar]
  • 2.Grichnik KP, Clark JA. Pathophysiology and management of one-lung ventilation. Thorac Surg Clin. 2005;15:85–103. doi: 10.1016/j.thorsurg.2004.09.004. [DOI] [PubMed] [Google Scholar]
  • 3.Senturk M. New concepts of the management of one-lung ventilation. Curr Opin Anaesthesiol. 2006;19:1–4. doi: 10.1097/01.aco.0000192778.17151.2c. [DOI] [PubMed] [Google Scholar]
  • 4.Baudouin SV. Lung injury after thoracotomy. Br J Anaesth. 2003;91:132–342. doi: 10.1093/bja/aeg083. [DOI] [PubMed] [Google Scholar]
  • 5.Licker M, de Perrot M, Spiliopoulos A, Robert J, Diaper J, Chevalley C, et al. Risk factors for acute lung injury after thoracic surgery for lung cancer. Anesth Analg. 2003;97:1558–1565. doi: 10.1213/01.ANE.0000087799.85495.8A. [DOI] [PubMed] [Google Scholar]
  • 6.Jeon K, Yoon JW, Suh GY, Kim J, Kim K, Yang M, et al. Risk factors for post-pneumonectomy acute lung injury/acute respiratory distress syndrome in primary lung cancer patients. Anaesth Intensive Care. 2009;37:14–19. doi: 10.1177/0310057X0903700110. [DOI] [PubMed] [Google Scholar]
  • 7.Eguchi T, Yoshida K, Kondo R, Hamanaka K, Shiina T, Komatsu Y, et al. Sivelestat prevents cytoskeletal rearrangements in neutrophils resulting from lung re-expansion following one-lung ventilation during thoracic surgery. Inflammation. 2013;36:1479–1484. doi: 10.1007/s10753-013-9689-9. [DOI] [PubMed] [Google Scholar]
  • 8.Misthos P, Katsaragakis S, Theodorou D, Milingos N, Skottis I. The degree of oxidative stress is associated with major adverse effects after lung resection: a prospective study. Eur J Cardiothorac Surg. 2006;29:591–595. doi: 10.1016/j.ejcts.2005.12.027. [DOI] [PubMed] [Google Scholar]
  • 9.Misthos P, Katsaragakis S, Milingos N, Kakaris S, Sepsas E, Athanassiadi K, et al. Postresectional pulmonary oxidative stress in lung cancer patients. The role of one-lung ventilation. Eur J Cardiothorac Surg. 2005;27:379–382. doi: 10.1016/j.ejcts.2004.12.023. [DOI] [PubMed] [Google Scholar]
  • 10.Funakoshi T, Ishibe Y, Okazaki N, Miura K, Liu R, Nagai S, et al. Effect of re-expansion after short-period lung collapse on pulmonary capillary permeability and pro-inflammatory cytokine gene expression in isolated rabbit lungs. Br J Anaesth. 2004;92:558–563. doi: 10.1093/bja/aeh101. [DOI] [PubMed] [Google Scholar]
  • 11.Brodsky JB, Fitzmaurice B. Modern anesthetic techniques for thoracic operations. World J Surg. 2001;25:162–166. doi: 10.1007/s002680020014. [DOI] [PubMed] [Google Scholar]
  • 12.Determann RM, Royakkers A, Wolthuis EK, Vlaar AP, Choi G, Paulus F, et al. Ventilation with lower tidal volumes as compared with conventional tidal volumes for patients without acute lung injury: a preventive randomized controlled trial. Crit Care. 2010;14:R1. doi: 10.1186/cc8230. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Schultz MJ, Haitsma JJ, Slutsky AS, Gajic O. What tidal volumes should be used in patients without acute lung injury? Anesthesiology. 2007;106:1226–1231. doi: 10.1097/01.anes.0000267607.25011.e8. [DOI] [PubMed] [Google Scholar]
  • 14.Ishikawa S, Lohser J. One-lung ventilation and arterial oxygenation. Curr Opin Anaesthesiol. 2011;24:24–31. doi: 10.1097/ACO.0b013e3283415659. [DOI] [PubMed] [Google Scholar]
  • 15.Della Rocca G, Coccia C. Ventilatory management of one-lung ventilation. Minerva Anestesiol. 2011;77:534–536. [PubMed] [Google Scholar]
  • 16.Shelley B, Macfie A, Kinsella J. Anesthesia for thoracic surgery: a survey of UK practice. J Cardiothorac Vasc Anesth. 2011;25:1014–1017. doi: 10.1053/j.jvca.2011.06.018. [DOI] [PubMed] [Google Scholar]
  • 17.Senturk NM, Dilek A, Camci E, Senturk E, Orhan M, Tugrul M, et al. Effects of positive end-expiratory pressure on ventilatory and oxygenation parameters during pressure-controlled one-lung ventilation. J Cardiothorac Vasc Anesth. 2005;19:71–75. doi: 10.1053/j.jvca.2004.11.013. [DOI] [PubMed] [Google Scholar]
  • 18.Tugrul M, Camci E, Karadeniz H, Senturk M, Pembeci K, Akpir K. Comparison of volume controlled with pressure controlled ventilation during one-lung anaesthesia. Br J Anaesth. 1997;79:306–310. doi: 10.1093/bja/79.3.306. [DOI] [PubMed] [Google Scholar]
  • 19.Heimberg C, Winterhalter M, Struber M, Piepenbrock S, Bund M. Pressure-controlled versus volume-controlled one-lung ventilation for MIDCAB. Thorac Cardiovasc Surg. 2006;54:516–520. doi: 10.1055/s-2006-924413. [DOI] [PubMed] [Google Scholar]
  • 20.Kang WS, Kim SH, Woo CJ. Comparison of Pulmonary Gas Exchange According to Intraoperative Ventilation Modes for Mitral Valve Repair Surgery via Thoracotomy With One-Lung Ventilation: A Randomized Controlled Trial. J Cardiothorac Vasc Anesth. 2014;28:920–925. doi: 10.1053/j.jvca.2013.10.014. [DOI] [PubMed] [Google Scholar]
  • 21.Montes FR, Pardo DF, Charris H, Tellez LJ, Garzon JC, Osorio C. Comparison of two protective lung ventilatory regimes on oxygenation during one-lung ventilation: a randomized controlled trial. J Cardiothorac Surg. 2010;5:99. doi: 10.1186/1749-8090-5-99. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Higgins JPT, Green S. Cochrane Handbook for Systematic Reviews of Interventions version 5.1.0 [updated March 2011]. The Cochrane Collaboration; 2011. http://handbook.cochrane.org.
  • 23.Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327:557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Futier E, Constantin JM, Paugam-Burtz C, Pascal J, Eurin M, Neuschwander A, et al. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. N Engl J Med. 2013;369:428–37. doi: 10.1056/NEJMoa1301082. [DOI] [PubMed] [Google Scholar]
  • 25.Curtin F, Elbourne D, Altman DG. Meta-analysis combining parallel and cross-over clinical trials. III: The issue of carry-over. Stat Med. 2002;21:2161–2173. doi: 10.1002/sim.1207. [DOI] [PubMed] [Google Scholar]
  • 26.Pardos PC, Garutti I, Pineiro P, Olmedilla L, de la Gala F. Effects of ventilatory mode during one-lung ventilation on intraoperative and postoperative arterial oxygenation in thoracic surgery. J Cardiothorac Vasc Anesth. 2009;23:770–774. doi: 10.1053/j.jvca.2009.06.002. [DOI] [PubMed] [Google Scholar]
  • 27.Eren Ongur F, Erolcay H, Yuceyar L, Sayilgan C, Ongur M, Demirkaya A. The comparison of the effects of volume vs pressure controlled ventilation on recruitment maneuver during one lung ventilation. Gogus-Kalp-Damar Anestezi ve Yogun Bakim Dernegi Dergisi. 2010;16:16–22. [Google Scholar]
  • 28.Unzueta MC, Casas JI, Moral MV. Pressure-controlled versus volume-controlled ventilation during one-lung ventilation for thoracic surgery. Anesth Analg. 2007;104:1029–1033. doi: 10.1213/01.ane.0000260313.63893.2f. [DOI] [PubMed] [Google Scholar]
  • 29.Al Shehri AM, El-Tahan MR, Al Metwally R, Qutub H, El Ghoneimy YF, Regal MA, et al. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation. J Cardiothorac Vasc Anesth. 2014;28:892–896. doi: 10.1053/j.jvca.2013.09.012. [DOI] [PubMed] [Google Scholar]
  • 30.Campbell RS, Davis BR. Pressure-controlled versus volume-controlled ventilation: does it matter? Respir Care. 2002;47:416–424. [PubMed] [Google Scholar]
  • 31.MacIntyre NR. New modes of mechanical ventilation. Clin Chest Med. 1996;17:411–421. doi: 10.1016/S0272-5231(05)70324-5. [DOI] [PubMed] [Google Scholar]
  • 32.Nichols D, Haranath S. Pressure control ventilation. Crit Care Clin. 2007;23:183–199. doi: 10.1016/j.ccc.2006.12.005. [DOI] [PubMed] [Google Scholar]
  • 33.Al-Saady N, Bennett ED. Decelerating inspiratory flow waveform improves lung mechanics and gas exchange in patients on intermittent positive-pressure ventilation. Intensive Care Med. 1985;11:68–75. doi: 10.1007/BF00254777. [DOI] [PubMed] [Google Scholar]
  • 34.Prella M, Feihl F, Domenighetti G. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation. Chest. 2002;122:1382–1388. doi: 10.1378/chest.122.4.1382. [DOI] [PubMed] [Google Scholar]
  • 35.Marini JJ, Ravenscraft SA. Mean airway pressure: physiologic determinants and clinical importance--Part 1: Physiologic determinants and measurements. Crit Care Med. 1992;20:1461–1472. doi: 10.1097/00003246-199210000-00017. [DOI] [PubMed] [Google Scholar]
  • 36.Unzueta C, Tusman G, Suarez-Sipmann F, Bohm S, Moral V. Alveolar recruitment improves ventilation during thoracic surgery: a randomized controlled trial. Br J Anaesth. 2012;108:517–524. doi: 10.1093/bja/aer415. [DOI] [PubMed] [Google Scholar]
  • 37.Tusman G, Bohm SH, Sipmann FS, Maisch S. Lung recruitment improves the efficiency of ventilation and gas exchange during one-lung ventilation anesthesia. Anesth Analg. 2004;98:1604–1609. doi: 10.1213/01.ANE.0000068484.67655.1A. [DOI] [PubMed] [Google Scholar]
  • 38.Esteban A, Alia I, Gordo F, de Pablo R, Suarez J, Gonzalez G, et al. Prospective randomized trial comparing pressure-controlled ventilation and volume-controlled ventilation in ARDS. For the Spanish Lung Failure Collaborative Group. Chest. 2000;117:1690–1696. doi: 10.1378/chest.117.6.1690. [DOI] [PubMed] [Google Scholar]
  • 39.Kallet RH, Campbell AR, Dicker RA, Katz JA, Mackersie RC. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes. Respir Care. 2005;50:1623–1631. [PubMed] [Google Scholar]
  • 40.Fujita Y, Fujino Y, Uchiyama A, Mashimo T, Nishimura M. High peak inspiratory flow can aggravate ventilator-induced lung injury in rabbits. Med Sci Monit. 2007;13:BR95–100. [PubMed] [Google Scholar]
  • 41.Benumof JL. One-lung ventilation and hypoxic pulmonary vasoconstriction: implications for anesthetic management. Anesth Analg. 1985;64:821–833. doi: 10.1213/00000539-198508000-00014. [DOI] [PubMed] [Google Scholar]
  • 42.Saito T, Den S, Cheema SP, Tanuma K, Carney E, Carlsson C, et al. A single-injection, multi-segmental paravertebral block-extension of somatosensory and sympathetic block in volunteers. Acta Anaesthesiol Scand. 2001;45:30–33. doi: 10.1034/j.1399-6576.2001.450105.x. [DOI] [PubMed] [Google Scholar]
  • 43.Cheema SP, Ilsley D, Richardson J, Sabanathan S. A thermographic study of paravertebral analgesia. Anaesthesia. 1995;50:118–121. doi: 10.1111/j.1365-2044.1995.tb15092.x. [DOI] [PubMed] [Google Scholar]
  • 44.Garutti I, Quintana B, Olmedilla L, Cruz A, Barranco M, Garcia de Lucas E. Arterial oxygenation during one-lung ventilation: combined versus general anesthesia. Anesth Analg. 1999;88:494–499. doi: 10.1213/00000539-199903000-00005. [DOI] [PubMed] [Google Scholar]
  • 45.Manning HL. Peak airway pressure: why the fuss? Chest. 1994;105:242–247. doi: 10.1378/chest.105.1.242. [DOI] [PubMed] [Google Scholar]
  • 46.Slinger P. Pro: low tidal volume is indicated during one-lung ventilation. Anesth Analg. 2006;103:268–270. doi: 10.1213/01.ane.0000223701.24874.c8. [DOI] [PubMed] [Google Scholar]
  • 47.Boussarsar M, Thierry G, Jaber S, Roudot-Thoraval F, Lemaire F, Brochard L. Relationship between ventilatory settings and barotrauma in the acute respiratory distress syndrome. Intensive Care Med. 2002;28:406–413. doi: 10.1007/s00134-001-1178-1. [DOI] [PubMed] [Google Scholar]
  • 48.Michelet P, D’Journo XB, Roch A, Doddoli C, Marin V, Papazian L, et al. Protective ventilation influences systemic inflammation after esophagectomy: a randomized controlled study. Anesthesiology. 2006;105:911–919. doi: 10.1097/00000542-200611000-00011. [DOI] [PubMed] [Google Scholar]
  • 49.Licker M, Diaper J, Villiger Y, Spiliopoulos A, Licker V, Robert J, et al. Impact of intraoperative lung-protective interventions in patients undergoing lung cancer surgery. Crit Care. 2009;13:R41. doi: 10.1186/cc7762. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Kjaergard LL, Villumsen J, Gluud C. Reported methodologic quality and discrepancies between large and small randomized trials in meta-analyses. Ann Intern Med. 2001;135:982–989. doi: 10.7326/0003-4819-135-11-200112040-00010. [DOI] [PubMed] [Google Scholar]
  • 51.Slinger P, Scott WA. Arterial oxygenation during one-lung ventilation. A comparison of enflurane and isoflurane. Anesthesiology. 1995;82:940–946. doi: 10.1097/00000542-199504000-00017. [DOI] [PubMed] [Google Scholar]

Articles from BMC Anesthesiology are provided here courtesy of BMC

RESOURCES