Skip to main content
. 2016 Jun 17;311(2):H415–H425. doi: 10.1152/ajpheart.00082.2016

Fig. 5.

Fig. 5.

Steady-state vasodilation in response to rhythmic twitch contractions at 2 Hz and 4 Hz in WT and Cav2−/− mice. Vasodilator Capacity calculated as described in methods. Across vessel branch orders, diameter changes were 5–10 μm during 2-Hz contractions and 15–20 μm during 4-Hz contractions with no differences between WT and Cav2−/− mice. Summary data are means ± SE; n = 5 per group. #P < 0.05 for contraction duration across groups.