Table 3. Measures of sensitivity, specificity, accuracy, AUC, and Cut Off values using significantly different metabolite ratios in the four ROI in discrimination of OSAS patients from healthy controls with receiver operating characteristic curve analysis.
Cut Off | Sensitivity % | Specificity % | Accuracy % | AUC % | |
---|---|---|---|---|---|
Right Thalamus | |||||
Glx | 1.5 | 84.6 | 86.4 | 85.7 | 92.3 |
tCho | 0.4 | 84.6 | 73.9 | 77.8 | 82.3 |
mI | 1.1 | 81.8 | 81.0 | 81.3 | 84.2 |
Glu | 0.9 | 92.3 | 54.5 | 68.6 | 74.1 |
Gln | 0.3 | 100.0 | 47.6 | 66.7 | 77.4 |
GPC | 0.2 | 61.5 | 78.3 | 72.2 | 67.4 |
Asc | 0.8 | 63.6 | 90.9 | 81.8 | 75.4 |
Left Thalamus | |||||
tNAA | 1.3 | 61.5 | 90.5 | 79.4 | 82.1 |
tCho | 0.3 | 84.6 | 61.9 | 70.6 | 72.5 |
mI | 1.1 | 100.0 | 72.2 | 83.9 | 89.7 |
NAA | 0.9 | 100.0 | 61.5 | 85.7 | 76.9 |
Right Putamen | |||||
Glx | 1.4 | 69.2 | 78.9 | 75.0 | 78.9 |
tCho | 0.3 | 71.4 | 76.2 | 74.3 | 76.2 |
mI | 1.2 | 72.7 | 88.2 | 82.1 | 77.5 |
Glu | 1.1 | 76.9 | 84.2 | 81.3 | 82.6 |
GABA | 0.3 | 63.6 | 84.6 | 75.0 | 77.6 |
Left Putamen | |||||
Glx | 1.6 | 83.3 | 72.2 | 76.5 | 84.1 |
Glu | 1.3 | 83.3 | 76.9 | 78.9 | 78.2 |
GABA | 0.46 | 100.0 | 66.7 | 78.6 | 86.7 |
PE | 0.95 | 100.0 | 80.0 | 85.7 | 100.0 |