. 2016 Apr 22;474(10):2181–2187. doi: 10.1007/s11999-016-4811-6

Table 2.

Studies assessing dual mobility articulations in primary THA

Author, year (arranged chronologically) Sample size Minimum followup (years) Cup Dislocation (%) Fixation technique Polyethylene type
Farizon et al., 1998 [13] 135 10 Novae-1 cup (Orthodynamics Ltd, Gloucestershire, UK) 0.7 Cementless N/A
Guyen et al., 2007 [15] 167 2 Saturne cup (Amplitude, Neyron, France) 0 Cementless HMWPE
Bauchu et al., 2008 [3] 150 6 (mean) Third-generation POLARCUP (Smith & Nephew Orthopaedics AG, Rotkreuz, Switzerland) 0 N/A N/A
Hamadouche et al., 2012 [16] 168 5 Tregor unconstrained tripolar cup (Aston Medical, Saint Etienne, France) 2 Cementless UHMWPE
Bouchet et al., 2011 [5] 105 1 Novae (Orthodynamics Ltd); Stafit (Zimmer GmbH, Winterthur, Switzerland); Avantage (Biomet, Valence, France); Gyros cups (DePuy, Warsaw, IN, USA) 0 Cementless Not specified
Boyer et al., 2012 [6] 240 19 Novae tripodal (SERF) (Orthodynamics Ltd) 0 Cementless UHMWPE
Prudhon et al., 2013 [26] 105 8 (median) Quattro® (Groupe Lépine, Genay, France) 0.9 Cemented UHMWPE
Epinette et al., 2014 [11] 437 2 Restoration ADM acetabular system (Stryker Orthopaedics, Mahwah, NJ, USA) 0 Cemented HXLPE
Caton et al., 2014 [8] 105 10 Quattro® (Groupe Lépine, Genay, France) 0.9 Cemented Standard
Epinette, 2015 [10] 143 2 Restoration ADM acetabular system (Stryker Orthopaedics) 0 Cementless HXLPE
Mohammed et al., 2015 [20] 20 0.5 Serf Novae® Dual Mobility Acetabular cup (Orthodynamics Ltd) 0 Both Not specified
Chughtai et al.* 410 2 Modular Dual Mobility (Stryker Orthopaedics) 0 Cementless UHMWPE

* The present study; UHMWPE = ultrahigh-molecular-weight polyethylene; HXLPE = highly crosslinked polyethylene; N/A = not available.