Skip to main content
. 2016 Sep 7;16(1):161. doi: 10.1186/s12886-016-0336-8

Table 2.

Postoperative vault and pupil size in eyes undergoing implantation of ICL V4 and ICL V4c

Parameter ICL V4 ICL V4c
Time course 1 day 1 week 1 month 1 day 1 week 1 month
Pupil size (mm)
 Mean ± SD 1.82 ± 0.66 3.50 ± 0.70 3.59 ± 0.68 2.43 ± 0.76 3.26 ± 0.45 3.31 ± 0.53
 Range 1.02 ~ 3.63 2.01 ~ 5.54 2.31 ~ 5.52 1.21 ~ 3.95 2.11 ~ 4.75 2.23 ~ 4.84
Vault (um)
 Mean ± SD 303.68 ± 185.11 517.89 ± 160.07 521.32 ± 155.72 316.67 ± 186.89 495.13 ± 180.84 510.77 ± 175.51
 Range 0 ~ 680 270 ~ 920 290 ~ 980 0 ~ 690 150 ~ 850 190 ~ 860

ICL implantable collamer lens, SD standard deviation