Skip to main content
. 2016 Sep 15;42:308–315. doi: 10.1016/j.actbio.2016.06.012

Table 1.

Fatigue properties of fascicles and IFM from the SDFT and CDET. Data are displayed as mean ± SD. Significant differences between tendon types identified by: ap < 0.05; bp < 0.01; cp < 0.001.

Fascicles
Interfascicular matrix
SDFT CDET SDFT CDET
Diameter (mm) 0.33 ± 0.14 0.37 ± 0.09b



Load applied (N) 3.68 ± 1.46 4.80 ± 1.88 1.15 ± 0.85 1.29 ± 1.28



Stress applied (MPa) 52.81 ± 28.62 47.99 ± 22.26



Number of cycles to failure 2709 ± 4819 139 ± 157c 921 ± 1947 215 ± 145b



Gradient of maximum creep curve 0.0014 ± 0.0023 0.013 ± 0.012c 0.0029 ± 0.0039 0.0082 ± 0.0046b



Gradient of minimum creep curve 0.00059 ± 0.00099 0.0054 ± 0.0091c 0.0012 ± 0.0014 0.0039 ± 0.0031



Hysteresis (%): Cycle 1–10 26.26 ± 7.31 34.05 ± 7.92b 30.57 ± 12.24 41.57 ± 12.48
Cycle 11–19 14.91 ± 4.23 23.77 ± 6.60c 20.38 ± 7.73 29.06 ± 12.74
Mid test cycles 12.22 ± 3.70 21.48 ± 7.56c 15.08 ± 6.69 22.06 ± 7.63b
Last 10 cycles 39.93 ± 11.05 53.12 ± 15.86c 53.32 ± 10.06 69.44 ± 11.38b



Loading stiffness (N/mm): Cycle 1 5.21 ± 1.75 6.23 ± 1.97a 2.69 ± 1.23 2.82 ± 1.37
Cycle 10 5.18 ± 1.82 5.36 ± 2.00 2.50 ± 1.29 2.03 ± 1.25a
Mid test cycle 4.23 ± 1.51 5.36 ± 1.33 2.54 ± 1.05 1.90 ± 1.04
10 cycles before failure 2.85 ± 1.10 4.51 ± 1.27c 2.06 ± 0.74 1.43 ± 0.77
Last cycle 2.50 ± 0.88 3.68 ± 1.36c 1.57 ± 0.60 1.32 ± 0.86



Unloading stiffness (N/mm): Cycle 1 8.56 ± 3.43 10.54 ± 3.25 4.73 ± 1.64 5.50 ± 2.22
Cycle 10 7.38 ± 2.90 8.23 ± 2.76 4.08 ± 1.79 3.70 ± 2.05
Mid test cycle 6.46 ± 2.44 8.39 ± 1.70 3.86 ± 1.44 3.25 ± 1.59
10 cycles before failure 5.35 ± 1.84 7.83 ± 2.18a 3.62 ± 1.00 2.70 ± 1.43
Last cycle 5.89 ± 2.49 9.06 ± 4.46a 3.64 ± 1.26 4.05 ± 2.19



Elongation (mm): Cycles 1–10 0.063 ± 0.042 0.29 ± 0.25c
Cycles 1-failure 1.79 ± 0.49 1.42 ± 0.41a 2.18 ± 1.82 1.32 ± 0.72