TABLE I.

Filter-based air samples: concentration of amorphous silica (PVC filters)

Sample Type
(mg/m3)
Sampling Location
Average Flow Rate (L/min)
Process/Task
Air Volume (L)
Total Time Sampled (min)
Total ConcentrationA
Task Area WWT 3ft from filter change task 36 6.03 217 NDB
Background WWT on cart, 20ft from task area 333 5.99 1,995 ND
PBZ WWT filter changes 39 5.97 233 ND
PBZ Subfab tank change; mock-up replenish batch 22 5.99 132 ND
Task Area Subfab ND changing tanks and replenishing batch 29 6.11 177
Background Subfab 15ft from tanks 189 5.40 1,021 ND
PBZ WWT filter and pre-filter change of acid tank 33 6.11 200 ND
Task Area WWT filter and pre-filter change of acid tank 37 6.04 225 ND
PBZ Cleanroom set-up of CMP tool 25 6.04 151 ND
Task Area Cleanroom ND on workstation operator’s table near CMP tool 45 6.04 273
Background Cleanroom 5ft from CMP tool 209 5.64 1,167 ND
Task Area Subfab 2ft from slurry system 19 6.02 115 0.497C
A

No sample results yielded sufficient particulate to be sent for analysis of amorphous silica content.

B

ND = Non-detectable.

C

Value is between the limit of detection (50μg/sample) and the limit of quantification (180μg/sample); estimated result.