Skip to main content
. Author manuscript; available in PMC: 2017 Nov 1.
Published in final edited form as: J Occup Environ Hyg. 2016 Nov;13(11):840–846. doi: 10.1080/15459624.2016.1183014

Table III.

Tukey's multiple pairwise comparisons for the mean difference (dB) in measurements between different applications and microphones.

Application 1 Application 2 Mean 1 (dBA) N 1 Mean 2 (dBA) N 2 dif HSD Test Statistic
NoiSee SPLnFFT 1.49 441 1.70 486 0.22 2.89
NoiSee SoundMeter 1.49 441 1.35 486 0.13 1.63
SPLnFFT SoundMeter 1.70 486 1.35 486 0.35 4.52A
Microphone 1 Microphone 2
iMM-6 Internal 0.09 486 3.45 441 3.35 43.11A
iMM-6 i436 0.09 486 1.17 486 1.07 13.77A
Internal i436 3.45 441 1.17 486 2.28 29.34A
A

Indicates a significant (p<0.05) difference