Skip to main content
. 2016 Aug 22;113(36):9983–9988. doi: 10.1073/pnas.1606915113

Table S1.

Summary of all microbubble–cell behaviors, categorized by transmit pulse

Waveform Type 1 Type 2 Entry at nuc. Nuc. disp. Double sono. PI + PI − Total Entry cyto. only
0.5 MHz, 8-cycle 9 5 6 1 2 23 35 58 5
0.5 MHz, 4-cycle 20 4 2 4 1 31 37 68 1
1 MHz, 8-cycle 17 4 5 4 0 30 27 57 5
2 MHz, 8-cycle 21 6 6 1 2 36 29 65 6
2 MHz, 16-cycle 24 0 4 3 1 32 27 59 8
Total 91 19 23 13 6 152 155 307 25
Total % of PI + 59.4 12.4 15.0 8.5 3.9 100 N/A N/A 16.3
Total % 29.6 6.2 7.5 4.2 1.9 49.5 50.5 100 8.14

Peak negative acoustic pressures ranged from 0.1 to 0.4 MPa, 0.2 to 0.8 MPa, and 0.2 to 0.6 MPa for 0.5 MHz, 1 MHz, and 2 MHz, respectively. Type 1 and type 2 cytoplasmic PI entry, as well as entry at nucleus (Entry at nuc.), nucleus displacement (Nuc. disp.), double sonoporation (Double sono.), and entry in cytoplasm only (Entry cyto. only) are all defined as illustrated in Fig. S1.