Skip to main content
. Author manuscript; available in PMC: 2016 Sep 12.
Published in final edited form as: Endoscopy. 2014 Apr 25;46(9):735–744. doi: 10.1055/s-0034-1365463

Table 5.

Parameters adjusted to each part-task. Mean score ± SEM.

Adjustment Expert Intermediate Novice
Knob control
Transfer 10 objects between compartments 135±16 40 ± 15 0
Partitioned into 4 compartments; scope insertion depth made constant
Object materials tested; lubricious materials selected to increase difficulty 171±81 80 ±20 35±5
Locking mechanism for scope fixation finalized 133± 63 75 ±5 20±6
Torque
1 ring to be transferred sequentially between posts 139± 53 90 ±10 35±15
5 rings to be transferred from central post on floor to 5 posts on walls
Posts tilted upward to ease ring placement; height and location of central post adjusted 172±28 96 ±28 43±7
Object materials tested; rubbery rings selected 141±53 80 ±27 45±5
Wall posts moved and staggered to force torque movement
Retroflexion
10 objects to be transferred from the front to the back wall 30 ± 5 0
10 objects to be transferred from the back to the front wall 128±13 35 ±15 25±5
Length adjusted; posts tilted upward to prevent objects from falling; distance between posts adjusted to optimize object placement and full retroflexion
Object materials tested; gummy material selected
Entrance slot raised; front wall posts adjusted to allow full retroflexion 157± 27 66 ±10 25±5
Polypectomy
10 round objects to be snared and detached from different walls 229±34 50 ±20 57±9
Moved some polyps to corners to add challenge 215± 9 133 ± 53 40±15
Switched from round to flat objects to encourage snaring polyp base
Magnet, Velcro, rubber corks, earring backs tested; electronic polyps selected 253± 16 124± 44 35±5
Navigation1
2 different paths to be navigated, with target task at the end 30 ±5 60±8
5 paths; rearranged paths to equalize difficulty 163 ± 45 118 ± 58 80
Navigation tubes lined with soft pad and film to protect scope and reduce resistance
Target tasks tested: bell-ringing, tip deflection; foreign body retrieval selected
Alpha loop reduction task implemented prior to the navigation task 141±30 60 ±12 40±12
Loop reduction1
Tester required to scope through a preformed loop, then reduce 141±30 60 ±12 40±12
Pipe materials tested: PVC, flexible pipe, carved polystyrene
Loop shape adjusted to grasp scope; transparent roof implemented to support scope during loop reduction; alpha loop reduction moved before navigation

PVC, poly(vinyl chloride)

1

Loop reduction and navigation tasks were combined into a single part-task, reported as duplicate test scores.