Operating Conditions of the GSVR

Operating Conditions—Primary Phase (Gas)
Gas injection velocity (at inlet slots) m/s 55, 70, 85, 100, 110
Gas flow rate Nm3/s 0.4, 0.5, 0.6, 0.7, 0.8
Gas density (25°C, 1 atm) kg/m3 1.225
Operating Conditions—Secondary Phase (Solids)
Material HDPE HDPE HDPE PC
Diameter mm 1 1.5 2 2
Particle‐size distribution mm 0.9 ± 0.3 1.4 ± 0.4 1.8 ± 0.5 1.9 ± 0.6
Density kg/m3 950 950 950 1240
Solids loading kg 2, 3, 4, maximum capacity