Skip to main content
. 2016 Jun 20;30(10):3285–3295. doi: 10.1096/fj.201500079R

TABLE 1.

Biophysical parameters for hClC-1 WT, T335N, and WT + T335N channels

ClC-1 [Cl−] (mM) V0.5 Pototal[mV (k)] Pmintotal IC (pA/pF) SSC (pA/pF) Cells (n)
WT 134 −74 ± 1 (30 ± 1) 0.45 ± 0.04 −72 ± 6.7 50.5 ± 6 15
T335N 134 94 ± 5* (25 ± 2) 0.68 ± 0.06 −13 ± 2.9* 7.6 ± 2.2* 13
WT + T335N 134 −50 ± 3 (51 ± 2) 0.39 ± 0.03 −59 ± 6 31 ± 3.8 18
WT 4 −22.9 ± 1.3 (37 ± 1) 0.23 ± 0.03 35 ± 8.9 8
T335N 4 39.1 ± 4.4 (72 ± 5)* 0.45 ± 0.03* 5.8 ± 1* 10
WT + T335N 4 30.1 ± 6.7 (74 ± 8)* 0.17 ± 0.03 17.9 ± 6.3* 7

Data are means ± sem of the indicated number of cells. V0.5, half maximal activation potential; k, slope factor; Pmin, minimal value of Po measured at −90 mV; IC, instantaneous current measured at −60 mV; SSC, steady state current measured at +60 mV. *P < 0.05 compared with WT.