. 2016 Sep 15;11(9):e0162419. doi: 10.1371/journal.pone.0162419

Table 8. Theoretical bleed through for Qdot 565 in Cy3 filter, using semrocksearchlight.com.

Theoretical data single wave length LED LED white light
Name Qdot565 in Qdot filter Cy3 in Cy3 filter Qdot in Cy3 filter Qdot565 in Qdot filter Cy3 in Cy3 filter Qdot in Cy3 filter
Filter Set specific specific bleed through specific specific bleed through
Exciter FF02-435/40 FF01-543/22 FF01-543/22 FF02-435/40 FF01-543/22 FF01-543/22
Emitter FF01-496/LP FF01-593/40 FF01-593/40 FF01-496/LP FF01-593/40 FF01-593/40
Dichroic FF482-Di01 FF562-Di03 FF562-Di03 FF482-Di01 FF562-Di03 FF562-Di03
Fluorophore Emission Qdot 565 Cy3 Qdot 565 Qdot 565 Cy3 Qdot 565
Light Source CoolLED pE4000 Lumencor SOLA light engine
435 nm 525 nm 525 nm
Fluorescence Signal (mW) 2.71E-06 3.54E-06 1.86E-07 7.60E-07 8.39E-07 4.22E-08
Excitation Light Noise (mW) 1.29E-08 2.72E-09 2.72E-09 2.15E-08 1.49E-09 1.49E-09
Autofluorescence Noise (mW) 0.0000325 0.0000034 0.0000034 0.00000937 0.000000747 0.000000747
Signal-to-Noise Ratio 0.083442 1.039 0.054611 0.080983 1.1212 0.056396
Ratio single wave length /LED white light Qdot565 in Qdot filter Cy3 in Cy3 filter Qdot in Cy3 filter
specific specific bleed through
Fluorescence Signal (mW) 3.565789474 4.219308701 4.407582938 (1)
Excitation Light Noise (mW) 0.6 1.825503356 1.825503356 (2)
Autofluorescence Noise (mW) 3.468516542 4.551539491 4.551539491 (3)
Signal-to-Noise Ratio 1.030364397 0.926685694 0.968348819 (4)
Single wave length LED white light Ratio single wave length/white light LED (7)
Bleed through signal Qdot/specific signal Qdot (5) 0.06863 0.05553 1.23607
Bleed though into Cy3 / specific Cy3 (6) 0.05254 0.0503 1.04462

From the theoretical data, ratio between the data given for single wave length and the white light illumination were calculated. They suggest that:

(1) The fluorescence signal would be stronger with single wave length LED but this would lead to more bleed through too

(2) The light noise for Qdot would be better with single wave length LED but worse than the white light illumination for Cy3

(3) The autofluorescence for Qdot would be worse with single wave length LED for Cy3 and Qdot

(4) The signal to noise ratio would slightly better for Qdot with single wave length LED but worse for Cy3

(5) The equivalent of 6.86% of Qdot specific fluorescence would be observed through Cy3 filter with single wave length LED & 5.55% with LED white light

(6) The equivalent of 5.25% of Qdot specific would go through Cy3 filter with LED white light & 5.03% with LED white light

(7) There would be more bleed through with single wave length LED, about 1.2 time more than with white light LED