Skip to main content
. 2016 Sep 16;7:150. doi: 10.3389/fneur.2016.00150

Table 2.

Experimental configurations (particle diameter D, extension angle α+, maneuver velocity v) and the corresponding critical resting times (printed in bold) determined by stepper-motor and by lever-arm experiments (“X” indicates that a successful SM could not be performed for the tested range of resting times).

Particle diameter D Extension angle α+ Maneuver velocity v
90°/s 135°/s 180°/s
Stepper-motor experiments
180 μm 20° 29 s 26 s 24 s
250 μm X X X
250 μm 10° X 33 s 26 s
250 μm 20° 16 s 13 s 12 s
250 μm 30° 9 s 8 s 8 s
Lever-arm experiments
250 μm 20° 16 s (12 s) 11 s (8 s) 10 s (8 s)

For the lever-arm experiments, the lower values in parentheses indicate the critical resting times for which SMs were only intermittently successful.