Skip to main content
. Author manuscript; available in PMC: 2017 Oct 1.
Published in final edited form as: Acad Radiol. 2016 Jul 16;23(10):1221–1229. doi: 10.1016/j.acra.2016.05.009

Table B1.

Summary of Acquisition and Reconstruction Parameters. The Reconstruction Kernel is B40f (Filtered Backprojection) for all Reconstructions and Therefore Not Listed in the Table

Patient Number Acquisition Parameters
Reconstruction Parameters
Tube Voltage (kV) CTDIvol (mGy) Pitch Slice Thickness (mm) Slice Interval (mm)
1 100 7.6 0.8 5 5
2 100 18.4 0.35 2 2
3 100 13.0 0.8 5 5
4 100 11.8 0.8 3 2.5
5 120 11.6 1 3 2
6 120 25.5 0.8 5 5
7 120 16.5 0.8 5 5
8 100 10.0 0.8 5 5
9 100 11.4 0.8 5 5
10 100 7.1 0.6 5 5
11 100 9.9 0.8 5 5
12 120 23.4 0.75 3 2.5
13 100 12.0 0.8 5 5
14 100 16.8 0.6 2 1
15 100 20.1 0.6 2 1
16 120 26.4 0.6 3 2.5
17 100 17.7 0.6 2 1
18 100 5.5 0.8 5 5
19 100 8.4 0.6 5 5
20 100 6.3 0.6 5 5
21 120 16.8 0.7 5 5
22 120 22.5 0.8 3 2.5
23 100 8.0 0.8 5 5
24 120 16.6 0.8 5 5
25 120 29.9 0.35 2 1
26 120 17.5 0.8 5 5
27 120 14.6 0.6 5 5
28 120 24.9 0.6 5 5
29 120 16.8 0.8 5 5
30 120 18.6 0.8 5 5