Table 1. Data collection and refinement statistics for Hg2+-MerR.
Diffraction data | |
---|---|
X-Ray source | Synchrotron |
Wavelength/Å | 1.0069 |
Detector | ADSC QUANTUM 315r CCD |
Diffraction conditions | 100 K under N2 cryostream |
Space group | P 31 2 1 |
Cell constants | 75.01 Å 75.01 Å 97.76 Å |
a, b, c, α, β, γ | 90.00° 90.00° 120.00° |
Resolution (Å) | 30−2.7 (2.8−2.7)* |
Rsym or Remerge | 0.077 (0.954) |
% Data completeness (in resolution range) | 98.4 (98.9) |
<I/σ(I)> | 31.05 (1.60) |
Redundancy | 3.8 (3.9) |
Refinement | |
Refinement program | REFMAC 5.7.0029 |
Resolution (Å) | 29.77–2.80 |
No. unique reflections | 7531 |
R work/R free | 0.230/0.266 |
No. atoms | |
Protein | 1810 |
Ligand | 2 |
Water | 1 |
B-factors | |
Protein | 93.570 |
Ligand | 127.185 |
Water | 68.010 |
R.m.s. deviations from ideality | |
Bond lengths/Å | 0.007 |
Bond angles/◦ | 1.033 |
Ramachandran plot** | |
Favored (%) | 98.2% |
Allowed (%) | 1.8% |
Disallowed (%) | 0 |
Protein Data Bank code | 5CRL |