Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2016 Sep 21;6:33599. doi: 10.1038/srep33599

A Facile Electrochemical Preparation of Reduced Graphene Oxide@Polydopamine Composite: A Novel Electrochemical Sensing Platform for Amperometric Detection of Chlorpromazine

Selvakumar Palanisamy 1, Balamurugan Thirumalraj 1, Shen-Ming Chen 1,a, Yi-Ting Wang 1, Vijayalakshmi Velusamy 2, Sayee Kannan Ramaraj 3
PMCID: PMC5030524  PMID: 27650697

Abstract

We report a novel and sensitive amperometric sensor for chlorpromazine (CPZ) based on reduced graphene oxide (RGO) and polydopamine (PDA) composite modified glassy carbon electrode. The RGO@PDA composite was prepared by electrochemical reduction of graphene oxide (GO) with PDA. The RGO@PDA composite modified electrode shows an excellent electro-oxidation behavior to CPZ when compared with other modified electrodes such as GO, RGO and GO@PDA. Amperometric i-t method was used for the determination of CPZ. Amperometry result shows that the RGO@PDA composite detects CPZ in a linear range from 0.03 to 967.6 μM. The sensor exhibits a low detection limit of 0.0018 μM with the analytical sensitivity of 3.63 ± 0.3 μAμM–1 cm–2. The RGO@PDA composite shows its high selectivity towards CPZ in the presence of potentially interfering drugs such as metronidazole, phenobarbital, chlorpheniramine maleate, pyridoxine and riboflavin. In addition, the fabricated RGO@PDA modified electrode showed an appropriate recovery towards CPZ in the pharmaceutical tablets.


Graphene has continuously received significant scientific interest from the theoretical chemists since the pioneering work of Geim and Novoselov et al. in 20041. As an alternative material to pristine graphene, a two dimensional (2D) carbon nanomaterial reduced graphene oxide (RGO) is also widely used for different applications owing to its distinct properties such as high surface area combined with remarkable mechanical, thermal and electrical properties2,3,4,5,6,7. To date, different reduction protocols have been employed for efficient reduction of graphene oxide (GO) into RGO such as, thermal reduction8, microwave and photo9, photo catalyst10, chemical11, solvothermal12 and electrochemical reduction methods13. Compared with the aforementioned reduction protocols, electrochemical reduction methods are found relatively simple, cost-effective, fast and environmentally friendly14. In addition, it is reported that electrochemically prepared RGO has retains some of the original properties of pristine graphene with new functionalities of RGO15.

Polydopamine (PDA) is a significant pigment of naturally occurring melanin (eumelanin) and has interesting of optical, electrical, and magnetic properties combined with excellent biocompatibility16,17,18. PDA also serves as a functional material for incorporating the various functional groups such as catechol, amine, and imine19,20. PDA can be easily incorporated within GO or RGO as a functional nanomaterial in wide range of biomolecular and electrochemical sensor applications21,22,23. Chlorpromazine (CPZ) is well-known antipsychotic drug, widely used in the treatment of schizophrenia, bipolar disorder and mania24,25. It is reported that the possible of risk of cancer is higher in patients undergoing continuous treatment with CPZ24. Therefore, the accurate and reliable detection of CPZ is essential to determine exposure levels.

To date, only a limited number of papers have focused on RGO@PDA composite for electrochemical sensor applications and all reported techniques for the fabrication of PDA incorporated RGO have done so by chemical methods22,23. In the present study, we have fabricated an RGO@PDA composite by a simple electrochemical method for the first time and utilized it as an advanced electrocatalyst for the oxidation of CPZ.

Herein, we report a selective and sensitive amperometric detection of CPZ using a novel composite of RGO@PDA modified electrode. The RGO@PDA composite shows a greater catalytic activity toward CPZ when compared with other modified electrodes. The stability, selectivity, and reproducibility of the sensor has been characterized and discussed in detail. The viability of the sensor has also been verified and critically assessed with pharmaceutical tablets containing the active ingredient, CPZ. The schematic representation for electrochemical fabrication of RGO@PDA composite is shown in Fig. 1.

Figure 1. Schematic representation for the electrochemical fabrication of RGO@PDA composite.

Figure 1

Results and Discussion

Characterizations

Figure 2 displays the SEM images of GO (A), GO@PDA (B), RGO (C) and RGO@PDA composite (D). The SEM image of GO shows its typical crumbled morphology with the associations of several nano graphite layers. The GO@PDA composite highlights an individual GO sheets with a thin layer of PDA embedded on the surface of GO without aggregation. The SEM image of RGO shows a creased and disintegrated morphology with ultra-thin RGO nanosheets that are randomly aggregated. In contrast, RGO@PDA composite shows a 3D morphology, where a thin layer of PDA uniformly covered the surface of RGO sheets. This may be attributable to the strong hydrophilic nature of DA entrapped directly on to the RGO sheets.

Figure 2.

Figure 2

SEM images of GO (A), GO@PDA (B), RGO (C) and RGO@PDA composite (D). Scale bar = 2 μM.

The presence of RGO and PDA was further confirmed by elemental analysis, and the corresponding elemental mapping is shown in Fig. 3B–D. The elemental mapping results confirmed the presence of carbon (B), oxygen (C) and nitrogen (D) in RGO@PDA composite, indicating the presence of RGO and PDA.

Figure 3.

Figure 3

(A) SEM image of RGO@PDA composite and corresponding elemental mapping of carbon (B), oxygen (C) and nitrogen (D).

The FT-IR and Raman spectroscopy confirms formation of the RGO@PDA composite. Raman spectroscopy is considered an ideal and informative technique for the characterization of carbon materials26. The G band in Raman spectra is resulting to the doubly degenerate phonon mode at the Brillouin zone center of sp2 carbon networks, while the D band is due to the disorder-induced phonon mode corresponding to scattering on the K-point phonon of sp2 carbon networks27. Figure 4A shows the typical Raman spectrum of GO (a), GO@PDA (b), RGO (c) and RGO@PDA composite (d). GO shows the D and G band at 1356 and 1593 cm−1, while, D and G band of GO@PDA is observed at 1358 and 1593 cm−1. The RGO@PDA composite shows D and G band at 1339 and 1604 cm−1, and the observed D and G bands are more consistent with Raman spectra of RGO. The observed shift of D and G bands in RGO@PDA composite is likely to result from the reduction of GO. The intensity ratio of D to G bands (ID/IG) of GO, GO@PDA, RGO and RGO@PDA were calculated as 0.92, 0.9, 1.04 and 1.02, respectively. The ID/IG results indicate the transformation of GO/PDA to RGO/PDA, and the ID/IG of RGO is consistent with those previously reported in the literature27.

Figure 4.

Figure 4

(A) Raman spectra of GO (a), GO@PDA (b), RGO (c) and RGO@PDA composite (d). (B) FT-IR spectra of GO (a), GO@PDA (b) and RGO@PDA composite (c).

FT-IR spectroscopy further confirms the formation of RGO@PDA composite. Figure 4B shows the FT-IR spectra of GO (a), GO@PDA (b) and RGO@PDA (c) composite. It can be seen that GO exhibits the bands at 3395, 2906, 1638, 1412, 1214 and 1051 cm−1 is corresponding to the vibrations of O-H stretching; vibration of C-H; bending vibration of adsorbed water; deformation of C–O and vibration modes of epoxide (C-O-C) respectively28. The result confirms the successful oxidation of graphite to GO. FT-IR of GO@PDA also shows a new characteristic peak at 1378 cm–1, ascribed to the vibration of phenolic C-O-H bending in PDA29. Furthermore, two distinguishing vibration peaks were observed at 1468 and 1378 cm–1, associated with the stretching vibration of C=N and C-N-C from PDA30. The bands at 1730, 1378 and 3811 cm–1 are due to the phenolic C-OH stretching vibration and O-H stretching vibrations of PDA30. The result confirms the formation of GO@PDA composite. In contrast, RGO@PDA composite exhibits the bands at 1292 and 1446 cm–1, associated with the vibration of phenolic C-O-H and stretching vibration of C=N from PDA30. Those bands related to -OH vibrations were significantly removed in RGO@PDA composite, which indicates efficient electrochemical reduction of GO@PDA to RGO@PDA.

Electrochemical behavior of CPZ

The electrochemical behavior of CPZ at different modified electrodes was investigated by CV. Figure 5 depicts the CV response obtained for GO (a), GO@PDA (b), RGO (c) and RGO@PDA (d) modified electrodes in the presence of 2 mM CPZ in N2 saturated PBS at a scan rate of 50 mV/s. The GO modified electrodes show a weak oxidation peak current response for CPZ at 0.71 V. The GO@PDA modified electrode shows an enhanced oxidation peak current response for CPZ at 0.735 V when compared to GO modified electrode. The result indicates that GO@PDA has enhanced detection of CPZ over the GO modified electrode. In contrast, the oxidation peak of CPZ was observed at 0.72 V in RGO modified electrode, and the current response was smaller than those observed in GO@PDA, which indicates that PDA has played significant role towards the enhancement of oxidation peak of CPZ. However, the RGO@PDA composite shows an oxidation peak at 0.763 V for CPZ. The oxidation peak current response of CPZ at RGO@PDA composite was 8.5, 2.5 and 4.4 fold higher than those detected at GO, GO@PDA and RGO modified electrodes (Fig. 5 inset) respectively. The enhanced activity of RGO@PDA composite towards CPZ may be due to the enrichment effect of PDA and high surface area of RGO. PDA serves as a possible matrix for adsorption of more CPZ on the electrode surface via strong π-π interaction between PDA and CPZ. The electron transfer between CPZ and electrode surface was further increased by the presence of RGO under diffusion conditions, thus resulting in enhanced oxidation peak current response to CPZ at the RGO@PDA composite modified electrode. The results indicate that RGO@PDA composite is more effective in the detection of CPZ when compared to other modified electrodes.

Figure 5. CV response of GO (a), GO@PDA (b), RGO (c) and RGO@PDA composite (d) modified electrodes in the presence of 2 mM CPZ in N2 saturated PBS at a scan rate of 50 mV/s.

Figure 5

The potential of CPZ and the oxidation peak current response at different modified electrodes are shown in the Inset. The error bars are relative to five measurements.

CV was applied to investigate the effect of scan rate on the electrochemical performance of CPZ at RGO@PDA composite modified electrode. Figure S1 shows the CV response of RGO@PDA composite modified electrode in 2 mM CPZ containing N2 saturated PBS at different scan rate from 20 to 200 mV/s (a–i). The oxidation peak current response of CPZ is directly proportional to the scan rate. Additionally, when the scan rates were increased from 20 to 200 mV/s, the peak potential underwent a negative shift. The anodic peak current of CPZ showed a linear relationship with the scan rate square root from 20 to 200 mV/s with a correlation coefficient of 0.9983 (Fig. S1 inset). It is evident from the results that the electrochemical oxidation of CPZ at RGO@PDA composite modified electrode is a diffusion controlled process31. Since the pH is crucial factor that can dramatically change the electrocatalytic activity of the modified electrode, the effect of pH on the oxidation peak current of CPZ was investigated by CV for the RGO@PDA composite modified electrode. Figure S2 shows the CV response obtained at RGO@PDA composite modified electrode in N2 saturated PBS containing 2 mM CPZ, at pH 3, pH 5, pH 7 and pH 9 containing 2 mM CPZ at a scan rate of 50 mV/s. A maximum oxidation peak current response of CPZ was observed at pH 7 (Fig. S2 inset) hence, pH 7 was used as an optimum pH for further experiments.

The electrocatalytic activity of the RGO@PDA composite modified electrode towards the oxidation of CPZ was studied by CV. Figure S3 displays the cyclic voltammetric response of RGO@PDA composite modified electrode in the absence (a’) and presence of concentrations of CPZ from 0.3–2.0 mM in N2 saturated PBS at a scan rate of 50 mV/s. In the absence of CPZ, no response was observed at the RGO@PDA composite electrode during the potential scanning from 0.1 to 1.0 V, indicating the composite modified electrode is electrochemically inactive in this potential range. In the presence of 0.3 mM (a) of CPZ, a sharp oxidation peak response was observed at 0.731 V. The oxidation peak current response of CPZ increases with the further addition of CPZ ((b) 0.7, (c) 1.0, (d) 1.5 and (e) 2.0) into the PBS, while the oxidation peak shifts towards positive direction. The electrochemical oxidation mechanism of CPZ at carbon modified electrodes is well studied and reported32. According to the early reports, it is believed that the electrochemical oxidation of CPZ occurs at nitrogen atoms, which corresponds to the oxidation peak of CV at 0.731 V. The electrochemical oxidation mechanism of CPZ at RGO@PDA composite modified electrode is shown in Fig. 6.

Figure 6. Electro-oxidation mechanism of CPZ at RGO@PDA composite modified electrode.

Figure 6

Amperometric determination of CPZ

To determine CPZ using RGO@PDA composite modified RDE, an amperometric i-t method was employed under optimum conditions. Figure 7 shows the amperometric i-t response for RGO@PDA composite modified RDE at different concentrations (0.003 to 1117.6 μM) of CPZ in constantly stirred N2 saturated PBS at a working potential of 0.8 V. A stable and well-defined amperometric i-t response was observed for the addition of 0.03 (a), 0.3 (b), 1 (c), 5 (d), 10 (e), 50 (f) and 100 μM (g) of CPZ into the PBS (Fig. 7 upper inset). Notably, the RGO@PDA composite modified electrode shows a sharp amperometric response for the addition of 0.03 (a) and 0.3 μM (b) of CPZ. The response time of the CPZ sensor was determined as 4 s, indicating the fast diffusion of CPZ on the modified electrode surface. The RGO@PDA composite modified electrode shows a stable amperometric response in a linear concentration range from 0.03 to 967.6 μM (Fig. 7 lower inset). The analytical sensitivity (slope/electrode active surface area) of the CPZ sensor was calculated as 3.63 ± 0.3 μAμM–1 cm–2 with a detection limit (LOD) of 0.0018 μM based on S/N = 3 (3∗standard deviation of the blank response)/slope of the calibration plot, Sd = 0.001 and slope = 0.167). The RGO@PDA composite modified electrode shows a lower LOD (1.8 nM) and a wider linear response (up to 967.6 μM) to CPZ when compared to the LOD and linear response range of graphene paste electrode (3 nM and 9.0 μM)32, carbon nanotube-polyethyleneimine electrode (10 nM and 115.4 μM)33, poly-3-methylthiophene combined with γ-cyclodextrin composite electrode (0.2 μM and 3 μM)34 and Alizarin Red modified electrode (5.16 μM and 500.0 μM)25. In addition, the observed sensitivity (3.63 ± 0.3 μAμM–1 cm–2) of the present sensor is higher than all aforementioned modified electrodes for the detection of CPZ. However, the LOD of the present sensor is higher than the LOD (0.01 nM) of previously reported GO based electrochemiluminescence CPZ sensor35. The result confirms that the RGO@PDA composite modified electrode may be used for the sensitive and low level electrochemical detection of CPZ.

Figure 7. Amperometric i-t response of RGO@PDA composite modified RDE in the presence of different additions (0.003 to 1117.6 μM) of CPZ into constantly stirred N2 saturated PBS.

Figure 7

Working potential = 0.8 V. Inset (upper) shows the enlarged amperometric response of RGO@PDA composite for the addition of 0.03 μM (a), 0.3 μM (b), 1 μM (c), 5 μM (d), 10 μM (e), 50 μM (f) and 100 μM (g) of CPZ into PBS. Inset (lower) shows the calibration plot for amperometric current response of vs. [CPZ].

Selectivity of the sensor

Evaluation of sensor selectivity is more important in real samples since other drugs can potentially interfere with the amperometric signal of CPZ. Therefore, amperometric i-t method was used to evaluate the selectivity of the RGO@PDA composite modified electrode. Figure S4A shows the amperometric i-t response obtained at RGO@PDA composite modified RDE for the addition of 1 μM of CPZ (a) and 100 μM of metronidazole (b), phenobarbital (c), chlorpheniramine maleate (d), pyridoxine (e), riboflavin (f) and ascorbic acid (g) into constantly stirred N2 saturated PBS at a working potential of 0.8 V. A well-defined amperometric response was observed for each addition of 1 μM CPZ, while 100 μM additions of potentially interfering drugs did not show any amperometric response on RGO@PDA composite modified electrode. The result indicates the high selectivity of RGO@PDA composite modified electrode towards CPZ, which is due to the strong π-π interaction between PDA and CPZ than that of other drugs. The high selectivity of RGO@PDA composite modified electrode further confirmed its use in the selective detection of CPZ in real samples.

Determination CPZ in pharmaceutical tablets

In order to evaluate the practicability of RGO@PDA composite towards CPZ, the modified electrode was evaluated for detection of CPZ in pharmaceutical tablets using amperometry. The experimental conditions are similar as of in Fig. 7. Prior to real sample analysis, the WINSUMIN (12.5 mg) CPZ tablet stock solutions were prepared by dissolving an appropriate number of WINSUMIN tablets into PBS. A known concentration of real sample was spiked into PBS and used for real sample analysis. Prior to analysis, an un-known concentration of CPZ in WINSUMIN tablets is determined as 28.6 μM by using standard addition method32 and the same method was used to determine the detection and the recovery of CPZ as listed in Table ST1. The RGO@PDA composite modified electrode shows a recovery of CPZ ranging from 98.5 to 99.2% in WINSUMIN tablets. The result validates that RGO@PDA composite modified electrode has a satisfactory recovery towards CPZ and may be used for the quantification of CPZ in pharmaceutical tablets.

Stability, precision and accuracy of the sensor

The operational stability of CPZ sensor was evaluated by amperometry. Figure S4B shows amperometric i-t response of RGO@PDA composite modified RDE for addition of 50 μM of CPZ (a) into constantly stirred N2 saturated PBS and its background current response up to 2000 s. The RGO@PDA composite modified electrode retains 93.2% of initial response of CPZ even after continuous run up to 2000 s and the result indicates good operational stability of the developed CPZ sensor. The storage stability was evaluated by CV under similar experimental conditions as in Fig. 5. The RGO@PDA composite modified electrode lost only 7.2% of initial current response to CPZ following storage in 2 mM containing PBS, indicating the satisfactory storage stability of the modified electrode. The reproducibility and repeatability of RGO@PDA composite modified electrode were investigated using CV and working conditions are similar as of in Fig. 5. The relative standard deviation (RSD) of 3.9% was found for three RGO@PDA composite modified electrodes for detection of 2 mM CPZ. An RSD of approximately 4.6% was observed for 10 measurements of a single RGO@PDA composite modified electrode in 2 mM CPZ containing PBS. These results indicate that RGO@PDA composite modified electrode has an appropriate reproducibility and repeatability for the detection of CPZ.

Conclusions

In conclusion, a novel RGO@PDA composite has been prepared by a simple electrochemical method and used for selective amperometric detection of CPZ. SEM, Raman and FTIR results confirm formation of the RGO@PDA composite. The RGO@PDA composite modified electrode showed greater catalytic activity towards CPZ than other modified electrodes. It showed excellent analytical characteristics for the detection of CPZ lower LOD (0.0018 μM), fast response (4 s), high sensitivity (3.63 ± 0.3 μAμM–1 cm–2) and wider response range (up to 967.6 μM). In addition, RGO@PDA modified electrode had a high selectivity towards CPZ in the presence of potentially interfering other drugs. Effective recovery of CPZ in pharmaceutical tablets further confirms RGO@PDA composite modified electrode as a suitable electrode material for the detection of CPZ. In addition, we believe that the novel RGO@PDA composite represents an attractive material for applications in biomedical and sensor fields.

Experimental

Materials and Methods

Chlorpromazine hydrochloride (≥98%) was obtained from Sigma–Aldrich and used as received. Dopamine was purchased from Sigma–Aldrich. Graphite power with an average diameter of about >20 μm was obtained from Sigma–Aldrich. NaH2PO4 was purchased from Sigma–Aldrich Company and Na2HPO4 was obtained from Avantor Performance Materials Inc, Center Valley, U.S.A. The WINSUMIN 12.5 mg chlorpromazine tablets were purchased from a local pharmaceutical company in Taipei, Taiwan. The WINSUMIN tablet samples were prepared by dissolving an appropriate amount of WINSUMIN tablets into phosphate buffer solution (PBS) pH 7.0. All other chemical were used in this study were obtained from Aldrich and the solutions were prepared using doubly distilled water without any further purification. The supporting electrolyte 0.05 mol L–1 pH 7 PBS solution was prepared by using 0.05 mol L–1 Na2HPO4 and NaH2PO4 solutions in double distilled water.

Cyclic voltammetry (CV) and amperometric i-t measurements were performed by computerized CHI 1205b electrochemical work station. Scanning electron microscopic (SEM) images were taken using Hitachi S-3000 H electron microscope. Raman spectra were acquired using a Raman spectrometer (Dong Woo 500i, Korea) equipped with a charge-coupled detector. Fourier transform infrared spectroscopy (FT-IR) was carried out using the Thermo SCIENTIFIC Nicolet iS10 instrument. HORIBA EMAX X-ACT attached Hitachi S-3000 H scanning electron microscope was used to perform energy-dispersive X-ray spectrum and elemental mapping. Amperometric i–t measurements were performed with an analytical rotator AFMSRX (PINE instruments, USA). Typical three electrode setup was used for electrochemical measurements, where glassy carbon electrode as a working electrode, a saturated Ag/AgCl reference electrode and a platinum electrode as an auxiliary electrode. A rotating disk electrode (RDE) with an electrochemically active surface area (EASA) of 0.046 cm2 was used for amperometric i-t measurements. The EASA of RGO@PDA composite modified RDE was calculated by CV, as reported early36. All electrochemical measurements were carried out at a room temperature in an inert atmosphere unless otherwise stated.

Synthesis of RGO@PDA composite

Graphite oxide was prepared from graphite powder by Hummers method as reported elsewhere28. The GO@PDA composite was prepared by our previously reported method37. Briefly, graphene oxide (GO) solution was prepared by dispersing of graphite oxide (2 mg mL–1) into DI water and followed by sonication for 30 min. Approximately 10 mg of DA was added into GO solution (10 mL) and solution pH was adjusted to 8.5 using 40% NH4OH under magnetic string. The reaction mixture was continuously stirred up to 2 h in room temperature. According to early reports, DA can be self-polymerized to form a PDA thin film directly on surface of GO37. The obtained GO@PDA composite was further purified and separated by filtration. The final GO@PDA composite was washed with DI water and ethanol, dried in an air oven, and re-dispersed in DI water for experimental use.

To fabricate RGO@PDA composite modified electrode, 8 μL of GO@PDA composite solution was dropped on pre-cleaned GCE and dried in an air oven. Then, GO@PDA composite modified electrode was transferred into an electrochemical cell containing pH 5 and applied a constant potential of –1.4 V for 300 s. Finally, GO@PDA composite was transformed into RGO@PDA composite (Fig. 1), and the resulting composite electrode was dried at room temperature. For comparison, a modified electrode of RGO only was prepared by the reduction of GO modified electrode in pH 5 without PDA. All modified electrodes were stored in room temperature under inert conditions when not in use.

Additional Information

How to cite this article: Palanisamy, S. et al. A Facile Electrochemical Preparation of Reduced Graphene Oxide@Polydopamine Composite: A Novel Electrochemical Sensing Platform for Amperometric Detection of Chlorpromazine. Sci. Rep. 6, 33599; doi: 10.1038/srep33599 (2016).

Supplementary Material

Supplementary Information
srep33599-s1.doc (769.5KB, doc)

Acknowledgments

This project was supported by the (Republic of China) Ministry of Science and Technology (project no. NSC1012113M027001MY3), Taiwan.

Footnotes

Author Contributions S.P. and B.T synthesized the RGO@PDA composite and B.T. and Y.-T.W. performed physicochemical and electrochemical experiments. S.P. prepared the figures and V.V., S.K.R. and S.-M.C. analyzed the data and prepared the manuscript draft. S.P. and S.-M.C. supervised and finalized the project. All authors discussed the results and contributed to the final manuscript.

References

  1. Geim A. K. & Novoselov K. S. The rise of graphene. Nat. Mater. 6, 183–191 (2007). [DOI] [PubMed] [Google Scholar]
  2. Eda G. & Chhowalla M. Chemically derived graphene oxide: towards large-area thin-film electronics and optoelectronics. Adv. Mater. 22, 2392–2415 (2010). [DOI] [PubMed] [Google Scholar]
  3. Hsieh C., Liu Y. & Roy A. K. Pulse electrodeposited Pd nanoclusters on graphene based electrodes for proton exchange membrane fuel cells. Electrochim. Acta. 64, 205–210 (2012). [Google Scholar]
  4. Chang H., Chang C., Tsai Y. & Liao C. Electrochemically synthesized graphene/polypyrrole composites and their use in supercapacitor. Carbon 50, 2331–2336 (2012). [Google Scholar]
  5. Raj M. A. & John S. A. Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrode. Anal. Chim. Acta. 771, 14–20 (2013). [DOI] [PubMed] [Google Scholar]
  6. Wang D., Yan W., Vijapur S. H. & Botte G. G. Electrochemically reduced graphene oxide–nickel nanocomposites for urea electrolysis. Electrochim. Acta. 89, 732–736 (2013). [Google Scholar]
  7. Zhao J., Pei S., Ren W., Gao L. & Cheng H. M. Efficient preparation of large-area graphene oxide sheets for transparent conductive films. ACS Nano 4, 5245–5252 (2010). [DOI] [PubMed] [Google Scholar]
  8. Zhu Y. et al. Microwave assisted exfoliation and reduction of graphite oxide for ultracapacitors. Carbon 48, 2118–2122 (2010). [Google Scholar]
  9. Cote L. J., Silva R. C. & Huang J. Flash reduction and patterning of graphite oxide and its polymer composite. J. Am. Chem. Soc. 131, 11027–11032 (2009). [DOI] [PubMed] [Google Scholar]
  10. Williams G., Seger B. & Kamat P. V. TiO2-graphene nanocomposites. UV-assisted photocatalytic reduction of graphene oxide. ACS Nano 2, 1487–1491 (2008). [DOI] [PubMed] [Google Scholar]
  11. Kotov N. A., De´ka´ny I. & Fendler J. H. Ultrathin graphite oxide–polyelectrolyte composites prepared by self-assembly: transition between conductive and non-conductive states. Adv. Mater. 8, 637–641 (1996). [Google Scholar]
  12. Wang H., Robinson J. T., Li X. & Dai H. Solvothermal reduction of chemically exfoliated graphene sheets. J. Am. Chem. Soc. 13, 9910–9911 (2009). [DOI] [PubMed] [Google Scholar]
  13. Toh S. Y., Loh K. S., Kamarudin S. K. & Daud W. R. W. Graphene production via electrochemical reduction of graphene oxide: Synthesis and characterization. Chem. Eng. J. 251, 422–434 (2014). [Google Scholar]
  14. Guo H. L., Wang X. F., Qian Q. Y., Wang F. B. & Xia X. H. A green approach to the synthesis of graphene nanosheets. ACS Nano 3, 2653–2659 (2009). [DOI] [PubMed] [Google Scholar]
  15. Viinikanoja A., Wang Z., Kauppila J. & Kvarnstrom C. Electrochemical reduction of graphene oxide and its in situ spectroelectrochemical characterization. Phys. Chem. Chem. Phys. 14, 14003–14009 (2012). [DOI] [PubMed] [Google Scholar]
  16. Liu Y., Ai K. & Lu L. Polydopamine and its derivative materials: synthesis and promising applications in energy, environmental, and biomedical fields. Chem. Rev. 114, 5057−5115 (2014). [DOI] [PubMed] [Google Scholar]
  17. Ball V. et al. Deposition mechanism and properties of thin polydopamine films for high added value applications in surface science at the nanoscale. BioNanoSci. 2, 16–34 (2012). [Google Scholar]
  18. Lynge M. E., Westen R., Postma A. & Städler B. Polydopamine-a nature-inspired polymer coating for biomedical science. Nanoscale 3, 4916–4928 (2011). [DOI] [PubMed] [Google Scholar]
  19. Lee H., Dellatore S. M., Miller W. M. & Messersmith P. B. Mussel-inspired surface chemistry for multifunctional coatings. Science 318, 426–430 (2007). [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Lee H. et al. Substrate-independent layer-by-layer assembly by using mussel-adhesive-inspired polymers. Adv. Mater. 20, 1619–1623 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Hu W. et al. Polydopamine-functionalization of graphene oxide to enable dual signal amplification for sensitive surface plasmon resonance imaging detection of biomarker. Anal. Chem. 86, 4488−4493 (2014). [DOI] [PubMed] [Google Scholar]
  22. Zheng L. et al. Facile preparation of polydopamine-reduced graphene oxide nanocomposite and its electrochemical application in simultaneous determination of hydroquinone and catechol. Sens. Actuators, B 177, 344– 349 (2013). [Google Scholar]
  23. Fu L., Lai G., Jia B. & Yu A. Preparation and electrocatalytic properties of polydopamine functionalized reduced graphene oxide-silver nanocomposites. Electrocatalysis 6, 72–76 (2015). [Google Scholar]
  24. Ensafi A. A. & Heydari E. Determination of some phenothiazines compounds in pharmaceuticals and human body fluid by electrocatalytic oxidation at a glassy carbon electrode using methylene blue as a mediator. Anal. Lett. 41, 2487–2502 (2008). [Google Scholar]
  25. Karimi M. A. et al. Electrocatalytic Determination of Chlorpromazine Drug Using Alizarin Red S as a Mediator on the Glassy Carbon Electrode. Russ. J. Electrochem. 47, 34–41 (2011). [Google Scholar]
  26. He Y. et al. Polydopamine-modified graphene oxide nanocomposite membrane for proton exchange membrane fuel cell under anhydrous conditions. J. Mater. Chem. A 2, 9548–9558 (2014). [Google Scholar]
  27. Qu K., Zheng Y., Dai S. & Qiao S. Z. Polydopamine–graphene oxide derived mesoporous carbon nanosheets for enhanced oxygen reduction. Nanoscale 7, 12598–12605 (2015). [DOI] [PubMed] [Google Scholar]
  28. Unnikrishnan B., Palanisamy S. & Chen S. M. A simple electrochemical approach to fabricate a glucose biosensor based on graphene–glucose oxidase biocomposite. Biosens. Bioelectron. 39, 70–75 (2013). [DOI] [PubMed] [Google Scholar]
  29. Jiang J., Jiang T., Wang Y., Du X., Wei Z. & Zhou H. Facile preparation of novel Au–polydopamine nanoparticles modified by 4-mercaptophenylboronic acid for use in a glucose sensor. RSC Adv. 4, 33658–33661 (2014). [Google Scholar]
  30. Nejad A. G., Aguilar L. E., Ambade R. B. Lee S. H., Park C. H. & Kim. C. S. Immobilization of silver nanoparticles on Electropolymerized polydopamine films for metal implant applications. Colloids Interface Sci. Commun. 6, 5–8 (2015). [Google Scholar]
  31. Łukasiewicz K. M., Tarasiewicz H. P. & Panuszko A. Electrochemical oxidation of phenothiazine derivatives at glassy carbon electrodes and their differential pulse and square‐wave voltammetric determination in pharmaceuticals. Anal. Lett. 41, 789–805 (2008). [Google Scholar]
  32. Parvin M. H. Graphene paste electrode for detection of chlorpromazine. Electrochem. Commun. 13, 366–369 (2011). [Google Scholar]
  33. Unnikrishnan B., Hsu P. C. & Chen S. M. A multipurpose voltammetric sensor for the determination of chlorpromazine in presence of acetaminophen, uric acid, dopamine and ascorbic Acid. Int. J. Electrochem. Sci. 7, 11414– 11425 (2012). [Google Scholar]
  34. Bouchta D., Izaoumen N., Zejli H., Kaoutit M. E. & Temsamani K. R. A. Novel electrochemical synthesis of poly-3-methylthiophene–cyclodextrin film application for the analysis of chlorpromazine and some neurotransmitters. Biosens. Bioelectron. 20, 2228–2235 (2005). [DOI] [PubMed] [Google Scholar]
  35. Liu F., Shao J. & Zhao Y. Electrochemiluminescence detection of chlorpromazine hydrochloride at bare and graphene oxide modified glassy carbon electrodes. Anal. Methods 6, 6483–6487 (2014). [Google Scholar]
  36. Karuppiah C., Palanisamy S., Chen S. M., Veeramani V. & Periakaruppan P. A. novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode. Sens. Actuators, B 196, 450–456 (2014). [Google Scholar]
  37. Palanisamy S., Thangavelu K., Chen S. M., Thirumalraj B. & Liu X. H. Preparation and characterization of gold nanoparticles decorated on graphene oxide@polydopamine composite: application for sensitive and low potential detection of catechol. Sens. Actuators, B 233(5), 298–306 (2016). [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep33599-s1.doc (769.5KB, doc)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES