Final stimulus levels used for hearing-impaired (HI) listeners. For each HI listener and each test frequency, the left-ear (“L”) and right-ear (“R”) hearing losses and the stimulus level used for each test are provided in this table, along with the high frequency used for each listener. In the high-frequency ILD task, lower-than-initially planned levels were used for HI3, HI5, and HI6, to avoid exceeding the subjects' discomfort thresholds. The same was true for all high-frequency tasks for HI4. Lower than initially planned levels were used for HI9 and HI10 in ILD at 2 kHz, to avoid exceeding the equipment ceiling.

500-Hz HL 500-Hz stimulus level High-frequency HL High-frequency stimulus level High-freq. test freq.
L R ITD ILD ICC L R ITD ILD ICC
HI1 25 20 75 75 75 55 50 85 85 85 4 kHz
HI2 30 35 75 75 75 45 40 85 85 85 4 kHz
HI3 35 25 75 75 75 50 45 85 75 85 4 kHz
HI4 15 15 75 75 75 65 65 85 85 85 4 kHz
HI5 35 35 85 80 80 55 60 90 88 90 4 kHz
HI6 50 55 80 80 80 60 60 85 80 85 4 kHz
HI7 40 35 80 80 80 80 75 DNM DNM DNM 4 kHz
HI8 55 55 85 85 85 70 70 98 DNM 98 4 kHz
HI9 75 65 90 90 90 75 75 100 95 100 2 kHz
HI10 65 65 95 95 95 85 75 100 95 100 2 kHz
HI11 55 55 85 85 85 95 95 DNM DNM DNM 2 kHz