Table 2. Textile OECT performance.

Geometry Non-textile (on glass)
Textile
G1
G1
G2
Linear range (M) Sensitivitya (LOD)c Linear range (M) Sensitivitya (LOD)c Sensitivityb (LOD)d
Ascorbic Acid 10−6–10−3 0.12 ± 0.01 (1.3 10−8) 10−4–10−2 0.37 ± 0.03 (1 10−5) 0.78 ± 0.05 (2.0)
Adrenaline 10−5–2 10−4 0.067 ± 0.007 (2 10−6) 3 10−5–5 10−4 0.75 ± 0.07 (1 10−5) 0.8 ± 0.1 (1.2)
Dopamine 10−6–10−4 0.10 ± 0.01 (5 10−8) 2 10−6–3 10−5 1.0 ± 0.2 (1 10−6) 1.1 ± 0.1 (0.4)

Parameters of calibration plots obtained in ideal conditions (geometry G1) and in real-life conditions (geometry G2) for a textile OECT and for an identical device fabricated on glass (ref. 31).

aExpressed as decade−1.

bExpressed as 105 C mol−1.

cExpressed as M.

dExpressed as 10−8 mol.