Skip to main content
. 2016 Sep 15;16(9):1500. doi: 10.3390/s16091500

Table 1.

Measurement results of width.

Wire Feed Rate (m/min) Voltage (V) Width
Vision System 3D Scanner
µ (mm) s (mm) µ (mm) s (mm)
3.9 21.0 6.16 0.38 6.18 0.37
4.5 23.0 6.87 0.36 6.92 0.48
4.5 19.0 5.69 0.27 5.72 0.28
6.0 23.8 7.80 0.35 7.85 0.46
6.0 21.0 6.79 0.34 6.83 0.38
6.0 18.2 5.84 0.43 5.87 0.60
7.5 23.0 8.16 0.50 8.22 0.53
7.5 19.0 6.23 0.77 6.30 0.78
8.1 21.0 7.70 0.45 7.71 0.29