Skip to main content
. 2016 Oct 5;6:34150. doi: 10.1038/srep34150

Figure 2.

Figure 2

(a) Transmittance spectrum and (b) relative photographs of O2 plasma treated and non-treated pristine AgNW and AgNW-IZO hybrid films; O2-p denotes plasma treated samples. (c) Optical microscope (OM) images of the AgNWs and the hybrid films on the released substrate before and after the adhesion test using Scotch tape. (d) Resistance variation of AgNW based films when exposed to temperature of 85 °C and (e) when immersed in solution with different pH values.