Skip to main content
. 2015 Jun 30;2(2):110–116. doi: 10.15441/ceem.14.016

Table 5.

Univariate logistic regression analysis and backward stepwise logistic regression model for prediction of the severity of pulmonary edema

Variable Odds ratio (95% CI) P-value
Univariate logistic regressiona)
 Shockable initial rhythm 0.50 (0.23–1.08) 0.078
 Total duration of CPR (/min) 1.05 (1.02–1.08) 0.002
 Albumin (/g/dL) 0.51 (0.28–0.93) 0.027
 Creatinine (/mg/dL) 1.52 (0.99–2.32) 0.054
 pO2 (/mmHg) 1.00 (0.99–1.00) 0.028
 pCO2 (/mmHg) 1.03 (1.01–1.04) 0.006
Backward stepwise logistic regression modelb)
 pCO2 (/mmHg) 1.02 (1.00–1.04) 0.038
 Total duration of CPR (/min) 1.04 (1.01–1.07) 0.016

CI, confidence interval; CPR, cardiopulmonary resuscitation.

a)

Variables significantly correlated with pulmonary edema severity (Table 4).

b)