Skip to main content
. 2016 Oct 10;6:34915. doi: 10.1038/srep34915

Table 2. Diagnostic and predictive values of pre-ablation Tg* and TSH* for a successful therapeutic outcome.

  Cutoff values Accuracy Sensitivity Specificity PPV* NPV* AUC* (95% CI*) P values
Pre-ablation Tg* 3.525 ng/mL 75.24% 77.12% 74.12% 64.09% 84.39% 0.843 (0.801–0.885) <0.001
Pre-ablation TSH* 99.700 μIU/ml 57.46% 57.63% 57.46% 44.74% 69.33% 0.605 (0.542–0.667) 0.002

*Tg = thyroglobulin, TSH = thyroid stimulating hormone, PPV = positive predictive value, NPV = negative predictive value, AUC = area under the curve, CI = confidence interval.