Table 4.
Echo Image Quality in Relation to LV Thrombus Detection*
Image Quality‡ | Endocardial Border Definition | LV Cavity Delineation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
Overall Population† | Pts with Thrombus Detected | Pts with Thrombus Missed | P | Overall Population† | Pts with Thrombus Detected | Pts with Thrombus Missed | P | Overall Population† | Pts with Thrombus Detected | Pts with Thrombus Missed | P | |
Non-Contrast Echo | 4.66±1.45 | 4.13±1.73 | 4.06±1.39 | 0.92 | 2.31±0.77 | 2.00±0.93 | 2.06±0.68 | 0.85 | 2.34±0.76 | 2.13±0.83 | 2.00±0.82 | 0.73 |
Contrast Echo | 5.44±0.89 | 5.21±0.89 | 4.56±1.24 | 0.15 | 2.61±0.59 | 2.50±0.52 | 2.22±0.67 | 0.28 | 2.83±0.42 | 2.71±0.47 | 2.33±0.71 | 0.13 |
Indices calculated using DE-CMR as the standard for LV thrombus
p<0.001 for all comparisons between contrast and non-contrast echo
Aggregate scale comprised of border definition and cavity delineation scores.