Skip to main content
. 2016 Sep 30;28(5):607–614. doi: 10.5021/ad.2016.28.5.607

Table 2. Erythema index results with pairwise comparisons between time periods.

Before treatment Short-term follow-up Long-term follow-up Between baseline and short-term follow-up Between baseline and long-term follow-up
Difference in means p-value Difference in means p-value
LPAN 17.3±2.3 16.0±2.6 16.7±2.4 1.36±1.23 <0.001 0.63±1.16 0.035
PDL 18.1±3.8 17.2±4.2 17.6±3.4 0.96±1.20 0.003 0.51±1.70 0.206

Values are presented as mean±standard deviation. LPAN: dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium: yttrium-aluminum-garnet laser, PDL: 585-nm pulsed dye laser. Short-term follow up: 2-week after the last treatment, long-term follow up: 6-month after the last treatment.